4.6 Article

CT FFR for Ischemia-Specific CAD With a New Computational Fluid Dynamics Algorithm A Chinese Multicenter Study

期刊

JACC-CARDIOVASCULAR IMAGING
卷 13, 期 4, 页码 980-990

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcmg.2019.06.018

关键词

computational fluid dynamics; fractional flow reserve; gray zone; intermediate lesions

资金

  1. National Key Research and Development Program of China [2017YFC0113400, 2016YFC1300300]
  2. Astellas
  3. Bayer
  4. General Electric
  5. Siemens Healthineers

向作者/读者索取更多资源

OBJECTIVES The aim of this study was to validate the feasibility of a novel structural and computational fluid dynamics-based fractional flow reserve (FFR) algorithm for coronary computed tomography angiography (CTA), using alternative boundary conditions to detect lesion-specific ischemia. BACKGROUND A new model of computed tomographic (CT) FFR relying on boundary conditions derived from structural deformation of the coronary lumen and aorta with transluminal attenuation gradient and assumptions regarding microvascular resistance has been developed, but its accuracy has not yet been validated. METHODS A total of 338 consecutive patients with 422 vessels from 9 Chinese medical centers undergoing CTA and invasive FFR were retrospectively analyzed. CT FFR values were obtained on a novel on-site computational fluid dynamics-based CT FFR (uCT-FFR [version 1.5, United-Imaging Healthcare, Shanghai, China]). Performance characteristics of uCT-FFR and CTA in detecting lesion-specific ischemia in all lesions, intermediate lesions (luminal stenosis 30% to 70%), and gray zone lesions (FFR 0.75 to 0.80) were calculated with invasive FFR as the reference standard. The effect of coronary calcification on uCT-FFR measurements was also assessed. RESULTS Per vessel sensitivities, specificities, and accuracies of 0.89, 0.91, and 0.91 with uCT-FFR, 0.92, 0.34, and 0.55 with CTA, and 0.94, 0.37, and 0.58 with invasive coronary angiography, respectively, were found. There was higher specificity, accuracy, and AUC for uCT-FFR compared with CTA and qualitative invasive coronary angiography in all lesions, including intermediate lesions (p < 0.001 for all). No significant difference in diagnostic accuracy was observed in the gray zone range versus the other 2 lesion groups (FFR <= 0.75 and >0.80; p = 0.397) and in patients with gray zone versus FFR <= 0.75 (p = 0.633) and versus FFR >0.80 (p = 0.364), respectively. No significant difference in the diagnostic performance of uCT-FFR was found between patients with calcium scores >= 400 and <400 (p = 0.393). CONCLUSIONS This novel computational fluid dynamics-based CT FFR approach demonstrates good performance in detecting lesion-specific ischemia. Additionally, it outperforms CTA and qualitative invasive coronary angiography, most notably in intermediate lesions, and may potentially have diagnostic power in gray zone and highly calcified lesions. (C) 2020 by the American College of Cardiology Foundation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据