4.7 Article

A highly sensitive biodegradable pressure sensor based on nanofibrous dielectric

期刊

SENSORS AND ACTUATORS A-PHYSICAL
卷 294, 期 -, 页码 140-147

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.sna.2019.05.021

关键词

Biodegradable; Piezo-capacitive; PLGA-PCL; Electrospinning; Nanofibers

资金

  1. Ministry of Trade, Industry and Energy (MOTIE)
  2. Korea Institute for Advancement of Technology (KIAT) through the International Cooperative RD program [P0006848]
  3. Ministry of Health & Welfare (MOHW), Republic of Korea [P0006848] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)
  4. National Research Foundation of Korea [22A20152913424] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

High performance biodegradable electronic devices are becoming popular due to their enormous applications as biomedical implants or short term communication devices. They are biocompatible and eco-friendly. For example wearable or implantable biodegradable pressure sensors are very useful for cardiovascular or blood flow monitoring. But unfortunately very few previous researches have focused on developing biodegradable pressure sensors. Here we propose a composite of Polylactic-co-glycolic acid (PLGA) and Polycaprolactone (PCL) for biodegradable piezo-capacitive pressure sensor fabrication for low pressure measurement in tactile ranges of (0 < P < 5 kPa). An electrospun PLGA-PCL composite membrane has been used as elastomeric dielectric sandwiched between two biodegradable iron-zinc (Fe-Zn) bilayer electrodes, deposited on degradable Polyvinyl alcohol (PVA) substrate using electron beam deposition, and encapsulated in PLGA thin films for device fabrication. PLGA-PCL nanofibrous dielectric membrane is highly compressible and porous having tunable mechanical as well as dielectric properties and has been reported first ever for biodegradable pressure sensor application. The sensitivity of the sensor was found to be 0.863 +/- 0.025 kPa(-1) in the low pressure region (0 < P <= 1.86 kPa) which is quite high as compared to previous literature on biodegradable sensors so far while it adapted to a value of 0.062 +/- 0.005 kPa(-1) for high pressure region (1.86 kPa < P <= 4.6 kPa). The lowest detected value was 1.24 Pa (at 10mgf). Sensor showed good average response and recovery times of 251 ms and 170 ms respectively. In vitro degradation studies of the sensor were performed in PBS solution and sensor lost 60% of its initial weight during first two weeks of degradation and continued to degrade even after that. After one week of incubation sensor showed a 19.5% decrease in low pressure measurement range while there was no significant difference in upper detection range. It has been used to measure the arterial pulse wave on wrist and a 4 x 4 pressure sensor array was made to demonstrate its use in mapping different pressure points. (C) 2019 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。