4.7 Review

Storage systems for building-integrated photovoltaic (BIPV) and building-integrated photovoltaic/thermal (BIPVT) installations: Environmental profile and other aspects

期刊

SCIENCE OF THE TOTAL ENVIRONMENT
卷 699, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.scitotenv.2019.134269

关键词

Storage materials; Building-integrated photovoltaic (BIPV); Building-integrated photovoltaic/thermal (BIPVT); Life cycle assessment (LCA); CO2 emissions, embodied energy; Human toxicity, ecotoxicity

资金

  1. Ministerio de Economia y Competitividad of Spain [ENE2016-81040-R]
  2. Institucio Catalana de Recerca i Estudis Avancats (ICREA)

向作者/读者索取更多资源

In recent years there has been an increasing interest in Building-Integrated Photovoltaic (BIPV) and Building-Integrated Photovoltaic/Thermal (BIPVT) systems since they produce clean energy and replace conventional building envelope materials. By taking into account that storage is a key factor in the effective use of renewable energy, the present article is an overview about storage systems which are appropriate for BIPV and BIPVT applications. The literature review shows that there are multiple storage solutions, based on different kinds of materials (batteries, Phase Change Material (PCM) components, etc.). In terms of BIPV and BIPVT with batteries or PCMs or water tanks as storage systems, most of the installations are non-concentrating, facade- or roof-integrated, water- or air-based (in the case of BIPVT) and include silicon-based PV cells, lead-acid or lithium-ion batteries, paraffin- or salt-based PCMs. Regarding parameters that affect the environmental profile of storage systems, in the case of batteries critical factors such as material manufacturing, accidental release of electrolytes, inhalation toxicity, flammable elements, degradation and end-of-life management play a pivotal role. Regarding PCMs, there are some materials that are corrosive and present fire-safety issues as well as high toxicity in terms of human health and ecosystems. Concerning water storage tanks, based on certain studies about tanks with volumes of 300 L and 600 L, their impacts range from 5.9 to 11.7 GJ(prim) and from 0.3 to 1.0 to CO2.eq. Finally, it should be noted that additional storage options such as Trombe walls, pebble beds and nanotechnologies are critically discussed. The contribution of the present article to the existing literature is associated with the fact that it presents a critical review about storage devices in the case of BIPV and BIPVT applications, by placing emphasis on the environmental profile of certain storage materials. (C) 2019 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据