4.7 Article

Thermal driven natural convective flows inside the solar chimney flush-mounted with discrete heating sources: Reversal and cooperative flow dynamics

期刊

RENEWABLE ENERGY
卷 138, 期 -, 页码 354-367

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.renene.2019.01.090

关键词

Thermal driven natural convection; Solar energy; Reversal flow; Discrete heat sources

资金

  1. Doctoral Kick-off Research Foundation of Henan University of Science and Technology [13480033]
  2. Natural Science Foundation of China (NSFC) [51778504, 51304233, 51208192]
  3. Joint Zhuzhou Hunan Provincial Natural Science Foundation [2018JJ4064]
  4. National Defense Research Funds for the Central Universities [2042018gf0031]
  5. Fundamental Research Projects from Shenzhen Government [JCYJ20160523160857948]
  6. National Key Research and Development Program of the Ministry of Science and Technology of China [2018YFC0705201, 2018YFB0904200]

向作者/读者索取更多资源

Fluid flow and heat transfer mechanism in a solar chimney induced by thermal buoyancy within a range of Ra numbers are reported by numerical and experimental investigations. The transport paths followed respectively by air and heat are visualized by streamlines and heatlines. Numerical results demonstrate that the reverse flow not only slows down the volume flow rate but also accelerates backflow presented in the solar chimney when Ra increases beyond a certain value, which makes the solar chimney lost its role of ventilation. In order to suppress the reverse flow and enhance ventilation performance, a solar chimney with multiple discrete sources flush attached the glazing wall is proposed. The effects of the sizes, positions, and numbers of those discrete heat sources on the system heat transfer rate and volume flow rate are discussed. After comparing with conventional solar chimney, the modified solar chimney with discrete heat source of height D-o =1 and position S-o =1 could perform better, not only preventing reverse flow but also enhancing the ventilation performance. The results obtained by the lab experimental measurements were agreed well with former numerical simulations. Temperature distributions along the heated wall for different heat input at ambient temperature illustrate the temperatures on the heated wall do not increase linearly and even drop near the top exit. This research could be significant for solar energy utilization and building energy conservation. (C) 2019 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据