4.6 Article

Are wearable heart rate measurements accurate to estimate aerobic energy cost during low-intensity resistance exercise?

期刊

PLOS ONE
卷 14, 期 8, 页码 -

出版社

PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pone.0221284

关键词

-

资金

  1. Norte Portugal Regional Operational Programme (NORTE 2020), through Portugal 2020
  2. European Regional Development Fund, NanoSTIMA [NORTE-01-0145-FEDER-000016]

向作者/读者索取更多资源

The aim of the present study was to assess the accuracy of heart rate to estimate energy cost during eight resistance exercises performed at low intensities: half squat, 45 inclined leg press, leg extension, horizontal bench press, 45 degrees inclined bench press, lat pull down, triceps extension and biceps curl. 56 males (27.5 +/- 4.9 years, 1.78 +/- 0.06 m height, 78.67 +/- 10.7 kg body mass and 11.4 +/- 4.1% estimated body fat) were randomly divided into four groups of 14 subjects each. Two exercises were randomly assigned to each group and subjects performed four bouts of 4-min constant-intensity at each assigned exercise: 12%, 16%, 20% and 24% 1-RM. Exercise and intensity order were random. Each subject performed no more than 2 bouts in the same testing session. A minimum recovery of 24h was kept between sessions. During testing VO2 was measured with Cosmed K4b2 and heart rate was measured with Polar V800 monitor. Energy cost was calculated from mean VO2 during the last 30-s of each bout by using the energy equivalent 1 ml O-2 = 5 calorie. Linear regressions with heart rate as predictor and energy cost as dependent variable were build using mean data from all subjects. Robustness of the regression lines was given by the scatter around the regression line (Sy.x) and Bland-Altman plots confirmed the agreement between measured and estimated energy costs. Significance level was set at p <= 0.05. The regressions between heart rate and energy cost in the eight exercises were significant (p<0.01) and robustness was: half squat (Sy.x = 0,48 kcal.min(-1)), 45 degrees inclined leg press (Sy.x = 0,54 kcal.min(-1)), leg extension (Sy.x = 0,59 kcal.min(-1)), horizontal bench press (Sy.x= 0,47 kcal.min(-1)), 45 inclined bench press (Sy.x = 0,54 kcal.min(-1)), lat pull down (Sy.x = 0,28 kcal.min(-1)), triceps extension (Sy.x = 0,08 kcal.min(-1)) and biceps curl (Sy.x = 0,13 kcal.min(-1)). We conclude that during low-intensity resistance exercises it is possible to estimate aerobic energy cost by wearable heart rate monitors with errors below 10% in healthy young trained males.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据