4.4 Article Proceedings Paper

Single-layer Compton detectors for measurement of polarization correlations of annihilation quanta

出版社

ELSEVIER
DOI: 10.1016/j.nima.2019.162835

关键词

Gamma-ray polarization; Positron Emission Tomography; Compton imaging

资金

  1. Croatian Agency for Small and Medium Enterprises, Innovations and Investments (HAMAG-BICRO) [POC6_1_211]
  2. Croatian Science Foundation [8570]
  3. International Atomic Energy Agency [CRP F22069]

向作者/读者索取更多资源

Measurement of gamma-ray polarization can provide valuable insight in different areas of physics research. One possible application is in Positron Emission Tomography, where the annihilation quanta with orthogonal polarizations are emitted. Since polarization can be measured via Compton scattering, the initial orthogonality of polarizations can be translated to correlation of azimuthal scattering angles, and this correlation may be exploited as an additional handle to identify the true coincidence events. In order to examine the concept of utilizing the polarization correlations in PET, we have used a system of two compact, position and energy-sensitive Compton scattering detectors in coincidence mode. Each consists of a single matrix of scintillation pixels, read-out by a matching array of Silicon photomultipliers on the back side. The Compton events in each module are clearly identified and the scattering angles are reconstructed from the energy deposition and event topology. We have extracted the polarimetric modulation factors from the measured azimuthal scattering angles of the two Compton-scattered gammas and studied their dependence on Compton scattering angles theta and on azimuthal resolution Delta phi. For scattering angles around theta(1,2) = 82 degrees, where the maximum modulation is expected, the modulation factors from mu = 0.15 +/- 0.01 to mu = 0.27 +/- 0.02 have been measured, depending on the azimuthal resolution, which is governed by event topology in the detectors. Analogously, for scattering around theta(1,2) = 70 degrees, modulation factors from mu = 0.12 +/- 0.01 to mu = 0.21 +/- 0.02 have been obtained. The results show that the measurement of the polarization correlations of annihilation quanta are feasible with compact single-layer, single-side read-out detectors, which may be used to build cost-efficient systems for various applications where gamma-ray polarization information is of interest.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据