4.6 Article

Preparation of phenyl-boronic acid polymeric monolith by initiator-free ring-opening polymerization for microextraction of sulfonamides prior to their determination by ultra-performance liquid chromatography-tandem mass spectrometry

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1609, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.chroma.2019.460510

关键词

Ring-opening polymerization; Polyether ether ketone tube; Phenyl-boronic acid polymeric monolith; Solid phase microextraction; Sulfonamides

资金

  1. National Natural Science Foundation of China [21605114]
  2. China Postdoctoral Science Foundation [2015T80226]
  3. Tianjin Natural Science Foundation [17JCQNJC13300]

向作者/读者索取更多资源

In this study, a novel phenyl-boronic acid polymeric monolith (PBAPM) in polyether ether ketone (PEEK) tube was fabricated. The inner wall of PEEK tube was modified with mussel inspired polydopamine layer to firmly bond PBAPM, so as to avoid the outflow of PBAPM from PEEK tube and improve the service life and application scope of PBAPM. The PBAPM was synthesized by initiator-free ring-opening polymerization based on our previous work. The boric acid groups provided B-N coordination sites, as well as the hydrophobic amino and epoxy monomers provided hydrophobic interaction sites. Due to the synergistic effect of hydrophobic interaction and B-N coordination, the PBAPM exhibited excellent binding amounts for nitrogen-containing sulfonamides (SAs). In addition, the PBAPM possessed excellent stability, rigidity and permeability. Therefore, the PBAPM was used as solid phase microextraction (SPME) material for enrichment and separation of SAs from aqueous samples. The PBAPM SPME was optimized in detail, and combined with ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) analysis for simultaneous determination of 10 kinds of SAs from tap, lake and river water. Using only 1 mL of water samples, limit of quantitation of SAs could reach 0.54-4.5 ng L-1. Recoveries of standard spiked SAs from water samples were between 82.0% and 105.4%, with intra-day and inter-day relative standard deviation ranging from 3.3% to 5.6% and 4.2% to 8.1%, respectively. The PBAPM SPME combined with UPLC-MS/MS method shown better or similar recoveries, and used fewer samples than previous methods. These results demonstrated that the PBAPM could selectively separate and enrich ultra-trace nitrogen-containing SAs from aqueous samples. (C) 2019 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据