4.6 Article Proceedings Paper

Profiling of polar metabolites in fruits of Opuntia stricta var. dillenii by ion-pair high-performance countercurrent chromatography and off-line electrospray mass-spectrometry injection

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1601, 期 -, 页码 274-287

出版社

ELSEVIER
DOI: 10.1016/j.chroma.2019.06.009

关键词

Opuntia stricta var. dillenii; Cactaceae; Betalains; Flavonoid glycosides; Off-line ESI-MS/MS injection metabolite profiling; Analytical/semi-preparative ion-pair high-performance countercurrent chromatography; Electrospray mass-spectrometry based metabolite partition ratio K-D-determination

资金

  1. Vietnamese National Foundation for Science and Technology Development

向作者/读者索取更多资源

Electrospray mass spectrometry-profiling guided the metabolome investigation of a C18 reversed phase adsorbate of Opuntia stricta var. dillenii fruits following analytical, and semi-preparative high-performance countercurrent chromatography (HPCCC) fractionation, and visualization of molecular weight elution profiles based on selected single ion-traces. Experimental partition-ratio values K-D, and peak widths for detected metabolites were determined. Structural characterization of metabolites, and co-elution effects were monitored in the scan range m/z 150-2200. The polar ion-pair activated solvent system tert.-butylmethylether - n-butanol - acetonitrile - water (0.7% trifluoroacetic acid) [2:2:1:5]) was used for partition-ratio K-D improvement of ionic betalains. HPCCC operations were in the head-to-tail mode using the elution-extrusion approach. Selected ESI-MS ion traces visualized the elution of fourty-three metabolites, whereas twenty-one were identified as known betalain pigments, and their classic degradation products, and chlorinated betacyanin artefacts. Potentially, novel fruit metabolites of Opuntia were recognized by unknown molecular weights, and MS/MS fragmentations. Off-line ESI-MS fraction monitoring determined peak elution windows, and resulted in K-D-based chromatographic scales. Detectable metabolites were compared by separation-alpha, and resolution factors Rs revealing a better performance of the analytical HPCCC experiment. Experimental metabolite K-D-values from analytical and semi-preparative HPCCC runs were widely consistent, and confirmed the reproducibility of the technique based on the used sample material. (C) 2019 Published by Elsevier B.V.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据