Estimating PTV Margins in Head and Neck Stereotactic Ablative Radiation Therapy (SABR) Through Target Site Analysis of Positioning and Intrafractional Accuracy

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.ijrobp.2019.09.010

关键词

-

资金

  1. National Science Foundation [NSF 1557559]
  2. National Institutes of Health [NIH 1R56DE025248-01, 1R25EB025787-01, 5R01CA214825-02, 5R01CA225190-02, 5R01CA218148-02, CA088084]

向作者/读者索取更多资源

Purpose: Recurrent or previously irradiated head and neck cancers (HNC) are therapeutically challenging and may benefit from high-dose, highly accurate radiation techniques, such as stereotactic ablative radiation therapy (SABR). Here, we compare set-up and positioning accuracy across HNC subsites to further optimize the treatment process and planning target volume (PTV) margin recommendations for head and neck SABR. Methods and Materials: We prospectively collected data on 405 treatment fractions across 79 patients treated with SABR for recurrent/previously irradiated HNC. First, interfractional error was determined by comparing ExacTrac x-ray to the treatment plan. Patients were then shifted and residual error was measured with repeat x-ray. Next, cone beam computed tomography (CBCT) was compared with ExacTrac for positioning agreement, and final shifts were applied. Lastly, intrafractional error was measured with x-ray before each arc. Results were stratified by treatment site into skull base, neck/parotid, and mucosal. Results: Most patients (66.7%) were treated to 45 Gy in 5 fractions (range, 21-47.5 Gy in 3-5 fractions). The initial mean +/- standard deviation interfractional errors were -0.2 +/- 1.4 mm (anteroposterior), 0.2 +/- 1.8 mm (craniocaudal), and -0.1 +/- 1.7 mm (left-right). Interfractional 3-dimensional vector error was 2.48 +/- 1.44, with skull base significantly lower than other sites (2.22 vs 2.77; P = .0016). All interfractional errors were corrected to within 1.3 mm and 1.8 degrees. CBCT agreed with ExacTrac to within 3.6 mm and 3.4 degrees. CBCT disagreements and intrafractional errors of >1 mm or >1 degrees occurred at significantly lower rates in skull base sites (CBCT: 16.4% vs 50.0% neck, 52.0% mucosal, P < .0001; intrafractional: 22.0% vs 48.7% all others, P < .0001). Final PTVs were 1.5 mm (skull base), 2.0 mm (neck/parotid), and 1.8 mm (mucosal). Conclusions: Head and neck SABR PTV margins should be optimized by target site. PTV margins of 1.5 to 2 mm may be sufficient in the skull base, whereas 2 to 2.5 mm may be necessary for neck and mucosal targets. When using ExacTrac, skull base sites show significantly fewer uncertainties throughout the treatment process, but neck/mucosal targets may require the addition of CBCT to account for positioning errors and internal organ motion. (C) 2019 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据