4.6 Article Proceedings Paper

Operating flexibility of natural gas combined cycle power plant integrated with post-combustion capture

期刊

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.ijggc.2019.04.023

关键词

CCS; Post-combustion CO2 capture; Gas turbine; Part load; Solvent storage; Centrifugal compressor

资金

  1. Engineering and Physical Sciences Research Council (EPSRC)

向作者/读者索取更多资源

Highly flexible, low-carbon electricity generation with gas-fired power stations with CO2 capture addresses the challenges of balancing variable renewable electricity supply in low carbon electricity systems. This detailed technical assessment of flexible CO2 capture plant operation at natural gas combined cycle power stations with post-combustion CO2 capture examines the operating strategies of capture plant by-pass and interim solvent storage. We show that solvent storage allows expanding the operating envelope of gas fired CCS power stations by +/- 10%. Further we demonstrate that electricity and CO2 output can be decoupled for up to 3 h with approx. 6000 m(3) of additional solvent inventory for the purpose of reducing the CO2 flow variability in downstream transportation and storage systems, mitigating potentially deleterious injection well effects. 1 h of solvent storage operation at full load can be regenerated in as fast as 2.1 h during continuous operation of the CCS power plant by choosing a controlled steam extraction strategy from the combined cycle and thus throttling the low pressure turbine. The electricity output penalty associated with the delayed regeneration of solvent ranges from 420-450 kWh/tCO(2) with this strategy, which compares to 380 kWh/tCO(2) for immediate regeneration at full load design conditions. By deploying a novel variable speed drive integrally geared compressor model, we find that, unlike previously thought, an uncontrolled steam extraction strategy, referred as a floating steam extraction strategy, can lead to choking of the CO2 compressor during additional solvent regeneration. A pre-compression stage would be necessary under this extraction strategy to restore feasible operation of the main CO2 compressor, and makes this strategy more complex to implement. When decreasing the desorber pressure at part-load care must, therefore, be taken to respect the operating limits of the compressor. To assist with the use of rigorous plant performance data in wider electricity system models, correlations for key performance parameters of NGCC-CCS power plants at varying load, with capture by-pass and additional solvent regeneration are provided.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据