4.6 Article

Debiasing-Based Noise Suppression for Ultrafast Ultrasound Microvessel Imaging

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TUFFC.2019.2918180

关键词

Noise suppression; power Doppler (PD); singular value decomposition (SVD); ultrafast ultrasound; ultrasound microvessel imaging (UMI)

资金

  1. National Cancer Institute of the National Institutes of Health [K99CA214523]
  2. National Institute of Diabetes and Digestive and Kidney Diseases [R01DK120559]

向作者/读者索取更多资源

Ultrasound microvessel imaging (UMI) based on the combination of singular value decomposition (SVD) clutter filtering and ultrafast plane wave imaging has recently demonstrated significantly improved Doppler sensitivity, especially to small vessels that are invisible to conventional Doppler imaging. Practical implementation of UMI is hindered by the high computational cost associated with SVD and low blood signalto- noise ratio (SNR) in deep regions of the tissue due to the lack of transmit focusing of plane waves. Concerning the high computational cost, an accelerated SVD clutter filtering method based on randomized SVD (rSVD) and randomized spatial downsampling (rSD) was recently proposed by our group, which showed the feasibility of real-time implementation of UMI. Concerning the low blood flow SNR in deep imaging regions, here we propose a noise suppression method based on noise debiasing that can be easily applied to the accelerated SVD method to bridge the gap between real-time implementation and high imaging quality. The proposed method experimentally measures the noise-induced bias by collecting the noise signal using the identical imaging sequence as regular UMI, but with the ultrasound transmission turned off. The estimated bias can then be subtracted from the original power Doppler (PD) image to obtain effective noise suppression. The feasibility of the proposed method was validated under different ultrasound imaging parameters [including transmitting voltages and time-gain compensation (TGC) settings] with a phantom experiment. The noise-debiased images showed an increase of up to 15.3 and 13.4 dB in SNR as compared to original PD images on the blood flow phantom and an in vivo human kidney data set, respectively. The proposed noise suppression method has negligible computational cost and can be conveniently combined with the previously proposed accelerated SVD clutter filtering technique to achieve high quality, real-time UMI imaging.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据