4.5 Article

Use of Cyclic Voltammetry to Describe the Electrochemical Behavior of a Dual-Chamber Microbial Fuel Cell

期刊

ENERGIES
卷 12, 期 18, 页码 -

出版社

MDPI
DOI: 10.3390/en12183532

关键词

dual-chamber MFC; cyclic voltammetry; electrolyte; electrochemical behavior; potentiostat settings; vacuum and non-pressurized conditions

向作者/读者索取更多资源

Cyclic voltammetry (CV) was used in this work to describe the electrochemical behavior of a dual-chamber microbial fuel cell (MFC). The system performance was evaluated under vacuum and non-pressurized conditions, different reaction times, two sweep potentials, 25 and 50 mVs(-1) and under different analyte solutions, such as distilled water and domestic wastewater. CV experiments were conducted by using a potentiostat with three different configurations to collect the measurements. A dual-chamber MFC system was equipped with a DupontTM Nafion (R) 117 proton exchange membrane (PEM), graphite electrodes (8.0 cm x 2.5 cm x 0.2 cm) and an external electric circuit with a 100-Omega resistor. An electrolyte (0.1 M HCl, pH approximate to 1.8) was used in the cathode chamber. It was found that the proton exchange membrane plays a major role on the electrochemical behavior of the MFC when CV measurements allow observing the conductivity performance in the MFC in the absence of a reference electrode; under this potentiostat setting, less current density values are obtained on the scanned window potentials. Therefore, potentiostat setting is essential to obtain information in complex electrochemical processes present in biological systems, such as it is the case in the MFCs. Results of the study showed that wastewater constituents and the biomass suspended or attached (biofilm) over the electrode limited the electron charge transfer through the interface electrode-biofilm-liquor. This limitation can be overcome by: (i) Enhancing the conductivity of the liquor, which is a reduction of the ohmic drop, (ii) reducing the activation losses by a better catalysis, and (iii) by limiting the diffusional gradients in the bulk liquor, for instance, by forced convection. The use of the electrolyte (0.1 M HCl, pH approximate to 1.8) and its diffusion from the cathode to the anode chamber reduces the resistance to the flow of ions through the PEM and the flow of electrons through the anodic and cathodic electrolytes. Also reduces the activation losses during the electron transfer from the substrate to the electrode surface due to the electrode catalysis improvement. On the other hand, vacuum also demonstrated that it enhances the electrochemical performance of the dual-chamber MFC due to the fact that higher current densities in the system are favored.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据