4.8 Article

Highly Compressible and Sensitive Pressure Sensor under Large Strain Based on 3D Porous Reduced Graphene Oxide Fiber Fabrics in Wide Compression Strains

期刊

ACS APPLIED MATERIALS & INTERFACES
卷 11, 期 40, 页码 37051-37059

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acsami.9b11596

关键词

graphene fibers; pressure sensor; flexible electronics; interface; fiber fabrics

资金

  1. National Natural Science Foundation of China [11632004, 21503025, U1864208]
  2. Key Program for International Science and Technology Cooperation Projects of Ministry of Science and Technology of China [2016YFE0125900]
  3. Fundamental Research Funds for the Central Universities [106112016CDJZR325520]
  4. Chongqing Research Program of Basic Research and Frontier Technology [cstc2016jcy-jA1059, cstc2017jcyjBX0063]
  5. China Postdoctoral Science [2018M633316]

向作者/读者索取更多资源

The development of highly sensitive wearable and foldable pressure sensors is one of the central topics in artificial intelligence, human motion monitoring, and health care monitors. However, current pressure sensors with high sensitivity and good durability in low, medium, and high applied strains are rather limited. Herein, a flexible pressure sensor based on hierarchical three-dimensional and porous reduced graphene oxide (rGO) fiber fabrics as the key sensing element is presented. The internal conductive structural network is formed by the rGO fibers which are mutually contacted by interfused or noninterfused fiber-to-fiber interfaces. Thanks to the unique structures, the sensor can show an excellent sensitivity from low to high applied strains (0.24-70.0%), a high gauge factor (1668.48) at an applied compression of 66.0%, a good durability in a wide range of frequencies, a low detection limit (1.17 Pa), and an ultrafast response time (30 ms). The dominated mechanism is that under compression, the slide of the graphene fibers through the polydimethylsiloxane matrix reduces the connection points between the fibers, causing a surge in electrical resistance. In addition, because graphene fibers are porous and defective, the change in geometry of the fibers also causes a change in the electrical resistance of the composite under compression. Furthermore, the interfused fiber-to-fiber interfaces can strengthen the mechanical stability under 0.01-1.0 Hz loadings and high applied strains, and the wrinkles on the surface of the rGO fibers increased the sensitivity under tiny loadings. In addition, the noninterfused fiber-to-fiber interfaces can produce a highly sensitive contact resistance, leading to a higher sensitivity at low applied strains.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据