期刊
SCIENTIFIC REPORTS
卷 9, 期 -, 页码 -出版社
NATURE PUBLISHING GROUP
DOI: 10.1038/s41598-019-44880-2
关键词
-
资金
- China Scholarship Council [201707040083]
A great number of fluorescent probes have been developed for detecting singlet oxygen (O-1(2)), which is considered to be one of the most effective reactive oxygen species (ROS), especially in clinical applications. The commercially available fluorescent probe Singlet Oxygen Sensor Green (SOSG) is widely used due to its reported high selectivity to O-1(2). In this study, we carried out systemic experiments to determine the activation of SOSG in the presence of ionizing radiation. The results show that the SOSG probe exhibits a pronounced fluorescence increase as a function of radiation dose delivered by gamma-rays as well as X-rays, in conditions where the formation of singlet oxygen is not expected. Furthermore, scavenger tests indicate that hydroxyl radicals may be involved directly or indirectly in the activation process of SOSG although the exact mechanism remains unknown.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐