4.7 Article

3D Super-Resolution US Imaging of Rabbit Lymph Node Vasculature in Vivo by Using Microbubbles

期刊

RADIOLOGY
卷 291, 期 3, 页码 642-650

出版社

RADIOLOGICAL SOC NORTH AMERICA
DOI: 10.1148/radiol.2019182593

关键词

-

资金

  1. Engineering and Physical Sciences Research Council [EP/N015487/1, EP/N014855/1, EP/M011933/1]
  2. Cancer Research UK Multidisciplinary Project Award [C53470/A22353]
  3. British Heart Foundation Centre of Research Excellence
  4. British Heart Foundation
  5. Engineering and Physical Sciences Research Council [EP/N014855/1] Funding Source: researchfish
  6. Medical Research Council [MR/S023542/1] Funding Source: researchfish
  7. EPSRC [EP/M011933/1, EP/N015487/1, EP/N014855/1] Funding Source: UKRI

向作者/读者索取更多资源

Background: Variations in lymph node (LN) microcirculation can be indicative of metastasis. The identification and quantification of metastatic LNs remains essential for prognosis and treatment planning, but a reliable noninvasive imaging technique is lacking. Three-dimensional super-resolution (SR) US has shown potential to noninvasively visualize microvascular networks in vivo. Purpose: To study the feasibility of three-dimensional SR US imaging of rabbit LN microvascular structure and blood flow by using microbubbles. Materials and Methods: In vivo studies were carried out to image popliteal LNs of two healthy male New Zealand white rabbits aged 6-8 weeks. Three-dimensional, high-frame-rate, contrast material-enhanced US was achieved by mechanically scanning with a linear imaging probe. Individual microbubbles were identified, localized, and tracked to form three-dimensional SR images and super-resolved velocity maps. Acoustic subaperture processing was used to improve image contrast and to generate enhanced power Doppler and color Doppler images. Vessel size and blood flow velocity distributions were evaluated and assessed by using Student paired t test. Results: SR images revealed microvessels in the rabbit LN, with branches clearly resolved when separated by 30 mu m, which is less than half of the acoustic wavelength and not resolvable by using power or color Doppler. The apparent size distribution of most vessels in the SR images was below 80 mu m and agrees with micro-CT data, whereas most of those detected with Doppler techniques were larger than 80 mu m in the images. The blood flow velocity distribution indicated that most of the blood flow in rabbit popliteal LN was at velocities lower than 5 mm/sec. Conclusion: Three-dimensional super-resolution US imaging using microbubbles allows noninvasive nonionizing visualization and quantification of lymph node microvascular structures and blood flow dynamics with resolution below the wave diffraction limit. This technology has potential for studying the physiologic functions of the lymph system and for clinical detection of lymph node metastasis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据