4.6 Article

Contrast-to-noise ratios and thickness-normalized, ventilation-dependent signal levels in dark-field and conventional in vivo thorax radiographs of two pigs

期刊

PLOS ONE
卷 14, 期 6, 页码 -

出版社

PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pone.0217858

关键词

-

资金

  1. Deutsche Forschungsgemeinschaft Gottfried Wilhelm Leibniz program
  2. European Research Council [AdG 695045]
  3. Deutsche Forschungsgemeinschaft [DFG EXC-158]

向作者/读者索取更多资源

Lung tissue causes significant small-angle X-ray scattering, which can be visualized with grating-based X-ray dark-field imaging. Structural lung diseases alter alveolar microstructure, which often causes a dark-field signal decrease. The imaging method provides benefits for diagnosis of such diseases in small-animal models, and was successfully used on porcine and human lungs in a fringe-scanning setup. Micro-and macroscopic changes occur in the lung during breathing, but their individual effects on the dark-field signal are unknown. However, this information is important for quantitative medical evaluation of dark-field thorax radiographs. To estimate the effect of these changes on the dark-field signal during a clinical examination, we acquired in vivo dark-field chest radiographs of two pigs at three ventilation pressures. Pigs were used due to the high degree of similarity between porcine and human lungs. To analyze lung expansion separately, we acquired CT scans of both pigs at comparable posture and ventilation pressures. Segmentation, masking, and forward-projection of the CT datasets yielded maps of lung thickness and logarithmic lung attenuation signal in registration with the dark-field radiographs. Upon correlating this data, we discovered approximately linear relationships between the logarithmic dark-field signal and both projected quantities for all scans. Increasing ventilation pressure strongly decreased dark-field extinction coefficients, whereas the ratio of lung dark-field and attenuation signal changed only slightly. Furthermore, we investigated ratios of dark-field and attenuation noise levels at realistic signal levels via calculations and phantom measurements. Dark-field contrast-tonoise ratio (CNR) per lung height was 5 to 10% of the same quantity in attenuation. We conclude that better CNR performance in the dark-field modality is typically due to greater anatomical noise in the conventional radiograph. Given the high physiological similarity of human and porcine lungs, the presented thickness-normalized, ventilation-dependent values allow estimation of dark-field activity of human lungs of variable size and inspiration, which facilitates the design of suitable clinical imaging setups.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据