4.6 Article

Sensitivity and specificity of an electronic nose in diagnosing pulmonary tuberculosis among patients with suspected tuberculosis

期刊

PLOS ONE
卷 14, 期 6, 页码 -

出版社

PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pone.0217963

关键词

-

资金

  1. Directorate General of Higher Education of Indonesia
  2. Devon Foundation, the Netherlands
  3. The eNose Company, Zutphen, the Netherlands

向作者/读者索取更多资源

Objective To investigate the potency of a hand-held point-of-care electronic-nose to diagnose pulmonary tuberculosis (PTB) among those suspected of PTB. Methods Setting: Lung clinics and Dr. Sardjito Hospital, Yogyakarta, Indonesia. Participants: patients with suspected PTB and healthy controls. Sampling: 5 minutes exhaled breath. Sputum-smear-microscopy, culture, chest-radiography, and follow-up for 1.5-2.5 years, were used to classify patients with suspected PTB as active PTB, probably active PTB, probably no PTB, and no PTB. After building a breath model based on active PTB, no PTB, and healthy controls (Calibration phase), we validated the model in all patients with suspected PTB (Validation phase). In each variable (sex, age, Body Mass Index, co-morbidities, smoking status, consumption of alcohol, use of antibiotics, flu symptoms, stress, food and drink intake), one stratum's Receiver Operating Characteristic (ROC)-curve indicating sensitivity and specificity of the breath test was compared with another stratum's ROC-curve. Differences between Area-under-the-Curve between strata (p<0.05) indicated an association between the variable and sensitivity-specificity of the breath test. Statistical analysis was performed using STATA/SE 15. Results Of 400 enrolled participants, 73 were excluded due to extra-pulmonary TB, incomplete data, previous TB, and cancer. Calibration phase involved 182 subjects, and the result was validated in 287 subjects. Sensitivity was 85% (95% CI: 75-92%) and 78% (95% CI: 70-85%), specificity was 55% (95% CI: 44-65%) and 42% (95% CI: 34-50%), in calibration and validation phases, respectively. Test sensitivity and specificity were lower in men. Conclusion The electronic-nose showed modest sensitivity and low specificity among patients with suspected PTB. To improve the sensitivity, a larger calibration group needs to be involved. With its portable form, it could be used for TB screening in remote rural areas and health care settings.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据