4.7 Article

Performance evaluation of a capacity-regulated high temperature heat pump for waste heat recovery in dyeing industry

期刊

APPLIED THERMAL ENGINEERING
卷 93, 期 -, 页码 1193-1201

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2015.10.075

关键词

High temperature heat pump; Twin screw compressor; Heat recovery; Capacity regulation

资金

  1. National Natural Science Foundation of China [51276134]

向作者/读者索取更多资源

In this paper, a capacity-regulated high temperature heat pump (HTHP) system using a twin-screw compressor was designed to recover waste heat in dyeing industry. The performance of the HTHP system was investigated under an on-site skein dyeing process condition. Results showed that the HTHP system could effectively utilize the waste heat at different temperatures to provide the energy required by the dyeing process. The heating capacity of the HTHP system could be well controlled to achieve the desired dyeing liquid temperature rising rate between 0.6 and 2.5 degrees C/min during different heating processes. The on-site testing results further demonstrated that the HTHP system could be reliably operated to heat the dyeing liquid temperature up to 95 degrees C with an average system COP of 4.2 during the entire heating process. Economic analysis indicated that the HTHP system could save about 47% of the operating cost in comparison to the traditional steam heating. (C) 2015 Elsevier Ltd. All rights reserved.