4.4 Article

Continuous monitoring of interstitial tissue oxygen using subcutaneous oxygen microsensors: In vivo characterization in healthy volunteers

期刊

MICROVASCULAR RESEARCH
卷 124, 期 -, 页码 6-18

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.mvr.2019.02.002

关键词

Medical device; Perfusion monitoring; Transcutaneous tissue oximetry; Vascular occlusion; Microcirculation; Subcutaneous oxygen microsensors

资金

  1. Profusa, Inc.
  2. Defense Advanced Research Projects Agency
  3. U.S. Army Research Office [W314Q-12-C-205, W911NF-11-0119, W911NF-16-1-0341]
  4. National Institutes of Health [R44HL131366, R42HL127933, R01EB016414]

向作者/读者索取更多资源

Measurements of regional tissue oxygen serve as a proxy to monitor local perfusion and have the potential to guide therapeutic decisions in multiple clinical disciplines. Transcutaneous oximetry (tcpO(2)) is a commercially available noninvasive technique that uses an electrode to warm underlying skin tissue and measure the resulting oxygen tension at the skin surface. A novel approach is to directly measure interstitial tissue oxygen using subcutaneous oxygen microsensors composed of a biocompatible hydrogel carrier platform with embedded oxygen sensing molecules. After initial injection of the hydrogel into subcutaneous tissue, noninvasive optical measurements of phosphorescence-based emissions at the skin surface are used to sense oxygen in the subcutaneous interstitial space. The object of the present study was to characterize the in vivo performance of subcutaneous microsensors and compare with transcutaneous oximetry (tcpO(2)). Vascular occlusion tests were performed on the arms of 7 healthy volunteers, with repeated tests occurring 1 to 10 weeks after sensor injection, yielding 95 total tests for analysis. Comparative analysis characterized the response of both devices to decreases in tissue oxygen during occlusion and to increases in tissue oxygen following release of the occlusion. Results indicated: (I) time traces returned by microsensors and tcpO(2) were highly correlated, with the median (inter quartile range) correlation coefficient of r = 0.93 (0.10); (II) both microsensors and tcpO(2) sensed a statistically significant decrease in normalized oxygen during occlusion (p < 0.001 for each device); (III) microsensors detected faster rates change (p < 0.001) and detected overshoot during recovery more frequently (38% vs. 4% of tests); (IV) inter-measurement analysis showed no correlation of baseline values between microsensors and tcpO(2) (r = 0.03), but comparison of integrated oxygen dynamics showed similar variation in the normalized response to occlusion between devices (p = 0.06), (V) intra-measurement analysis revealed that microsensors detect greater physiological fluctuations than tcpO(2) (p < 0.001) and may provide enhanced sensitivity to processes such as vasomotion. Additionally, the functional response of microsensors was not significantly different across time groupings (per month) post-injection (p = 0.61). Although the compared devices have differences in the mechanisms used to sense oxygen, these findings demonstrate that subcutaneous oxygen microsensors measure changes in interstitial tissue oxygen in human subjects in vivo.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据