4.7 Article

A hydrogel composite prepared from alginate, an amino-functionalized metal-organic framework of type MIL-101(Cr), and magnetite nanoparticles for magnetic solid-phase extraction and UHPLC-MS/MS analysis of polar chlorophenoxy acid herbicides

期刊

MICROCHIMICA ACTA
卷 186, 期 8, 页码 -

出版社

SPRINGER WIEN
DOI: 10.1007/s00604-019-3679-z

关键词

Green polymer; Porous material; MIL-101(Cr)-NH2; Nanoparticles; Orthogonal array design; Sample preparation; Liquid chromatography-tandem mass spectrometry; Halogenated compounds; Environmental water

资金

  1. National University of Singapore (NUS)
  2. NUS Environmental Research Institute [143-000-023-001]
  3. NUS Graduate School for Integrative Sciences and Engineering

向作者/读者索取更多资源

A regenerable hydrogel composite isdescribed that iscomprised of alginate, amino-functionalized metal-organic framework (MIL-101(Cr)-NH2) and magnetite nanoparticles. The composite was characterized by scanning electron microscopy, Fourier-transform infrared spectroscopy, vibrating-sample magnetometry and Brunauer-Emmett-Teller measurement. The material was applied to the magnetic solid-phase extraction of six polar chlorophenoxy acid (CPA) herbicides. Specifically, the herbicides clofibric acid, 4-chlorophenoxyacetic acid, 2,4-dichlorophenoxyacetic acid, 2-(2,4-dichlorophenoxy)propionic acid, 2,4,5-trichlorophenoxyacetic acid and 2-(2,4,5-trichlorophenoxy)propionic acid were extracted from environmental aqueous samples and analyzed by ultra-HPLC-tandem mass spectrometry. The abundance of hydroxyl and carboxyl groups on the natural polymer renders alginate a superior hydrophilic coating. It brings the polar acidic herbicides into closer proximity to the porous metal-organic framework. When integrated with MIL-101(Cr)-NH2, the composite material combines the favorable attributes of high hydrophilicity and large adsorption capacity. An orthogonal array design matrix was employed for the optimization of the extraction parameters. Under the most favorable conditions, the method displays a wide linear response and low limits of detection (0.43-16 ng.L-1). Precision and reproducibility (with relative standard deviations of <= 13%) are satisfactory. Enrichment factors range between 27 and 107. The composite was applied to the extraction of CPA herbicides from lake and pond water samples. A markedly improved sorbent-based extraction procedure and performance (compared to previous methods) is found.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据