4.5 Review

Indoor hospital air and the impact of ventilation on bioaerosols: a systematic review

期刊

JOURNAL OF HOSPITAL INFECTION
卷 103, 期 2, 页码 175-184

出版社

W B SAUNDERS CO LTD
DOI: 10.1016/j.jhin.2019.06.016

关键词

Bioaerosols; Indoor air; Hospital; Ventilation; Healthcare-acquired infections

资金

  1. Cystic Fibrosis Foundation Therapeutics USA [BELL14AO]
  2. Prince Charles Hospital Foundation [MS2014-20]
  3. NHMRC Early Career Fellowship [APP1036620]
  4. Thoracic Society of Australia and New Zealand/Vertex Adult Cystic Fibrosis Fellowship
  5. Queensland Health Research Fellowship [50007]
  6. Advance Queensland PhD Scholarships

向作者/读者索取更多资源

Healthcare-acquired infections (HAIs) continue to persist in hospitals, despite the use of increasingly strict infection-control precautions. Opportunistic airborne transmission of potentially pathogenic bioaerosols may be one possible reason for this persistence. Therefore, this study aimed to systematically review the concentrations and compositions of indoor bioaerosols in different areas within hospitals and the effects of different ventilation systems. Electronic databases (Medline and Web of Science) were searched to identify articles of interest. The search was restricted to articles published from 2000 to 2017 in English. Aggregate data was used to examine the differences in mean colony forming units per cubic metre (cfu/m(3)) between different hospital areas and ventilation types. A total of 36 journal articles met the eligibility criteria. The mean total bioaerosol concentrations in the different areas of the hospitals were highest in the inpatient facilities (77 cfu/m(3), 95% confidence interval (CI): 55-108) compared with the restricted (13cfu/m(3), 95% CI: 10-15) and public areas (14 cfu/m(3), 95% CI: 10-19). Hospital areas with natural ventilation had the highest total bioaerosol concentrations (201 cfu/m(3), 95% CI: 135-300) compared with areas using conventional mechanical ventilation systems (20 cfu/m(3), 95% CI: 16-24). Hospital areas using sophisticated mechanical ventilation systems (such as increased air changes per hour, directional flow and filtration systems) had the lowest total bioaerosol concentrations (9 cfu/m(3), 95% CI: 7-13). Operating sophisticated mechanical ventilation systems in hospitals contributes to improved indoor air quality within hospitals, which assists in reducing the risk of airborne transmission of HAIs. Crown Copyright (C) 2019 Published by Elsevier Ltd on behalf of The Healthcare Infection Society. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据