4.7 Article

Three-dimensional modeling of a PEMFC with serpentine flow field incorporating the impacts of electrode inhomogeneous compression deformation

期刊

INTERNATIONAL JOURNAL OF HYDROGEN ENERGY
卷 44, 期 39, 页码 22194-22209

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijhydene.2019.06.187

关键词

Proton exchange membrane fuel cell; Serpentine flow field; Assembly pressure; Gas diffusion layer; Compression deformation; Cell performance

资金

  1. National Key Research and Development Program of China [2017YFB0102703]
  2. National Natural Science Foundation of China [51876159]

向作者/读者索取更多资源

The effects of compression deformation of gas diffusion layer (GDL) on the performance of a proton exchange membrane fuel cell (PEMFC) with serpentine flow field were numerically investigated by coupling two-dimensional GDL mechanical deformation model based on Finite Element Analysis and three-dimensional two-phase PEMFC model with incorporating the deformation impacts. Emphasis is located on exploring the influences of assembly pressure on the non-uniform geometric deformation and distributions of transport properties in the GDL, flow behaviors and local distributions of oxygen and current density, cell polarization curves and net power densities of the PEMFC. It was indicated that the non-uniform deformation of GDL results in inhomogeneous distributions of porosity and permeability in the GDL due to the presence of rib-channel pattern, and the transport properties in the under-rib region are greatly reduced with increasing the assembly pressure, consequently weakening the gas flow and oxygen transport in the under-rib region and increasing the non-uniformity of local current density distribution. As for the overall cell performance, however, attributed to the tradeoff between the adverse impacts of GDL compression on mass transport loss and positive effects on reducing ohmic loss, the overall cell performance is firstly increased and then decreased with increasing assembly pressure from 0 MPa to 5.0 MPa, and the maximum cell performance can be achieved at the assembly pressure of about 1.0 MPa for all cases studied. As compared with the case for zero assembly pressure, the maximum net power density of the cell can be improved by about 7.7%, 9.9%, 10.5% and 10.7% for the cathode stoichiometry ratios of 2.0, 3.0, 4.0 and 5.0@i(ref) = 1 A.cm(-2), respectively. Practically, it is suggested that the assembly pressure is controlled in an appropriate range of 0.5 MPa-1.5 MPa such that the cell net power can be boosted and pressure head requirement for the pump can be maintained in a appropriate level. (C) 2019 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据