4.4 Article

Capability-coordinated frequency control scheme of a virtual power plant with renewable energy sources

期刊

IET GENERATION TRANSMISSION & DISTRIBUTION
卷 13, 期 16, 页码 3642-3648

出版社

INST ENGINEERING TECHNOLOGY-IET
DOI: 10.1049/iet-gtd.2018.5828

关键词

power grids; wind power plants; invertors; renewable energy sources; frequency control; power generation control; distributed power generation; pumped-storage power stations; WPP; VPP; AS-PSH; adjustable-speed pumped storage hydropower; virtual power plant; primary control loop; system frequency error; CCFC dispatches weighted frequency errors; local frequency control units; CCFC organises; hierarchical-control structure; CCFC scheme; energy storage system; wind power plant; future power systems; conventional power plants; electric power systems; inverter-based renewable energy; renewable energy sources; capability-coordinated frequency control scheme; largest control; modified frequency error; partial active power command; steady-state error; frequency nadir

资金

  1. US Department of Energy (DOE) [DE-AC36-08GO28308]
  2. US Department of Energy Office of Energy Efficiency and Renewable Energy Water Power Technologies Office

向作者/读者索取更多资源

Growing trends in the deployment of inverter-based renewable energy will decrease the inertia and frequency control capability of electric power systems by replacing conventional power plants; thus, the frequency of future power systems might be dynamic. This study proposes a capability-coordinated frequency control (CCFC) scheme of a virtual power plant (VPP) including adjustable-speed pumped storage hydropower (AS-PSH), a wind power plant (WPP), and an energy storage system to support the frequency nadir and reduce the steady-state error of system frequency. The CCFC scheme is based on a hierarchical-control structure in which a CCFC organises the output of local frequency control units. To support the frequency nadir, the CCFC dispatches weighted frequency errors that are proportional to the available headroom of the units; thus, the errors are forwarded separately with a system frequency error to the primary control loop of each unit and thereby arrest the frequency nadir at a higher value than a system without the CCFC. To reduce the steady-state error of the system frequency, the CCFC determines a partial active power command by additionally feeding an integrator of the CCFC with a modified frequency error that depends on the unit with the largest control.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据