4.7 Article

Through-the-scope placement of a fully covered metal stent for palliation of malignant dysphagia: a prospective cohort study (with video)

期刊

GASTROINTESTINAL ENDOSCOPY
卷 90, 期 6, 页码 972-979

出版社

MOSBY-ELSEVIER
DOI: 10.1016/j.gie.2019.06.030

关键词

-

资金

  1. Kebomed BV

向作者/读者索取更多资源

Background and Aims: To further optimize endoscopic stent placement, an esophageal fully covered self-expandable metal stent with a through-the-scope (TTS) delivery system was designed, providing direct endoscopic control during stent placement. The aim of the study was to assess the feasibility and safety of a TTS stent approach for palliation of malignant dysphagia. Methods: This multicenter prospective feasibility study included patients with malignant dysphagia undergoing stent placement. The primary outcome was technical success of TTS stent placement. Secondary outcomes included functional outcome, adverse events, and survival. Patients were prospectively evaluated at days 14 and 28, and monthly thereafter, until death or stent removal. Results: In total, 33 stents were placed in 32 patients. TTS stent placement was feasible in 30 (91%) procedures. In the other 3 procedures (9%), no large-channel endoscope could be introduced because of patient discomfort. In 10 (33%) TTS procedures, technical success was achieved because no fluoroscopy and/or guidewire was used, whereas in 20 (67%) TTS procedures, placement was supported by a guidewire (n = 9), or fluoroscopy and a guidewire (n = 11). After 2 weeks, dysphagia scores had improved in 24 (86%) patients. Median dysphagia-free timewas 32 days (interquartile range [IQR], 17-76 days). In 20 (63%) patients, 29 serious adverse events (SAEs) occurred. Recurrent dysphagia occurred in 13 (41%) patients due to migration (n = 5), tissue overgrowth (n = 4), and stent deformation (n = 4). Other SAEs included significant retrosternal pain (n = 4), hemorrhage (n = 2), and esophageal perforation (n = 1). No patient died from a stent-related cause. Median survival was 42 days (IQR, 28-91 days). Conclusion: Placement of an esophageal TTS stent was feasible in most of the patients with malignant dysphagia. However, stent placement was associated with a relatively high adverse event rate, and in more than one-third of patients, stent placement still required fluoroscopy, which limited optimal benefit of the TTS approach.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据