4.5 Article Proceedings Paper

Behaviour of load bearing double stud LSF walls in fire

期刊

FIRE SAFETY JOURNAL
卷 107, 期 -, 页码 15-28

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.firesaf.2019.05.003

关键词

Double stud wall; Single stud wall; Cold-formed steel construction; Fire tests; Fire behaviour

资金

  1. QUT
  2. Australian Research Council
  3. National Association of Steel Framed Housing (NASH)
  4. Stoddart Group

向作者/读者索取更多资源

In the residential sector single stud LSF walls are commonly used as load bearing and non-load bearing walls. But in situations where higher acoustic insulation levels and load bearing capacities are required, double stud LSF walls are used. However, fire performance of double stud LSF walls has not been investigated adequately unlike in the case of single stud LSF walls. There is insufficient research data on the fire performance of double stud wall systems. Therefore, this research investigated the fire performance of double stud walls under standard fire conditions using full scale test panels (3 m x 3 m) made of 90 mm lipped channel studs. Three full-scale fire tests were conducted to investigate the fire performance of load bearing double stud LSF walls. The fire test results of double stud LSF walls were then compared with those of single stud LSF walls with varying stud depth. The results revealed the presence of a unique heat transfer mechanism, resulting in an enhanced fire performance for double stud walls. The discontinuous stud arrangement within the cavity of double stud LSF walls was identified as the main contributor for the delayed heat transfer mechanism. This paper presents the details of this research and its results. It has also shown that the Direct Strength Method (DSM) based fire design equations developed for single stud LSF walls can be used to predict the failure times of double stud LSF walls exposed to fire.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据