4.7 Article

Assessment of hepatic steatosis by using attenuation imaging: a quantitative, easy-to-perform ultrasound technique

期刊

EUROPEAN RADIOLOGY
卷 29, 期 12, 页码 6499-6507

出版社

SPRINGER
DOI: 10.1007/s00330-019-06272-y

关键词

Fatty liver; Ultrasonography; Biopsy; Sensitivity and specificity; Linear models

向作者/读者索取更多资源

Objectives To evaluate the diagnostic performance of attenuation imaging (ATI) in the detection of hepatic steatosis compared with a histopathology gold standard. Methods We prospectively enrolled 108 consecutive patients (35 males; median age, 54.0 years) who underwent percutaneous liver biopsy for evaluation of diffuse liver disease between January 2018 and November 2018 in a tertiary academic center. Grayscale ultrasound examination with ATI was performed just before biopsy, and an attenuation coefficient (AC) was obtained from each patient. The degree of hepatic steatosis, fibrosis stage, and necroinflammatory activity were assessed on histopathologic examination. The significant factor associated with the AC was found by a linear regression analysis, and the diagnostic performance of the AC for the classification into each hepatic steatosis stage was evaluated by receiver operating characteristic (ROC) analysis. Results The distribution of hepatic steatosis grade on histopathology was 53/11/22/16/6 for none/mild (< 10%)/mild (>= 10%)/moderate/severe steatosis, respectively. The area under the ROC curve, sensitivity, specificity, and optimal cutoff AC value for detection of hepatic steatosis ranged from 0.843-0.926, 74.5-100.0%, 77.4-82.8%, and 0.635-0.745, respectively. Multivariate analysis revealed that the degree of steatosis was the only significant determinant factor for the AC. Conclusions The AC from ATI provided good diagnostic performance in detecting the varying degrees of hepatic steatosis. The degree of steatosis was the only significant factor affecting the AC, whereas fibrosis and inflammation were not. Key Points Attenuation imaging (ATI) is based on two-dimensional grayscale ultrasound images that can incorporate into routine ultrasound examinations with less than 2 min of acquisition time. ATI provided good diagnostic performance in detecting the varying degrees of hepatic steatosis with an area under the ROC curves ranging from 0.843 to 0.926, and there was no technical failure in this study indicating high applicability of this technique. The degree of hepatic steatosis was the only significant factor affecting the result of ATI examination.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据