Catecholaminergic polymorphic ventricular tachycardia; Implantable cardioverter-defibrillator; Secondary prevention; Sudden cardiac arrest; Sudden cardiac death

资金

  1. ZonMW Priority Medicines for Rare Diseases and Orphan Drugs [113304045]
  2. National Health and Medical Research Council (NHMRC Practitioner Fellowship) [1059156]
  3. Mayo Clinic Windland Smith Rice Comprehensive Sudden Cardiac Death Program
  4. Netherlands Federation of University Medical Centres
  5. Netherlands Organisation for Health Research and Development
  6. Royal Netherlands Academy of Sciences [CVON 2012-10]
  7. E-Rare Joint Transnational Call

向作者/读者索取更多资源

Aims In patients with catecholaminergic polymorphic ventricular tachycardia (CPVT), implantable cardioverter-defibrillator (ICD) shocks are sometimes ineffective and may even trigger fatal electrical storms. We assessed the efficacy and complications of ICDs placed in patients with CPVT who presented with a sentinel event of sudden cardiac arrest (SCA) while undiagnosed and therefore untreated. Methods and results We analysed 136 patients who presented with SCA and in whom CPVT was diagnosed subsequently, leading to the initiation of guideline-directed therapy, including beta-blockers, flecainide, and/or left cardiac sympathetic denervation. An ICD was implanted in 79 patients (58.1%). The primary outcome of the study was sudden cardiac death (SCD). The secondary outcomes were composite outcomes of SCD, SCA, appropriate ICD shocks, and syncope. After a median follow-up of 4.8 years, SCD had occurred in three patients (3.8%) with an ICD and none of the patients without an ICD (P = 0.1). SCD, SCA, or appropriate ICD shocks occurred in 37 patients (46.8%) with an ICD and 9 patients (15.8%) without an ICD (P < 0.0001). Inappropriate ICD shocks occurred in 19 patients (24.7%) and other device-related complications in 22 patients (28.9%). Conclusion In previously undiagnosed patients with CPVT who presented with SCA, an ICD was not associated with improved survival. Instead, the ICD was associated with both a high rate of appropriate ICD shocks and inappropriate ICD shocks along with other device-related complications. Strict adherence to guideline-directed therapy without an ICD may provide adequate protection in these patients without all the potential disadvantages of an ICD.