4.7 Article

The elastic and ductile behaviour of CLT wall-floor connections and the influence of fastener length

期刊

ENGINEERING STRUCTURES
卷 189, 期 -, 页码 319-331

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.engstruct.2019.03.100

关键词

Capacity based design; Cross Laminated Timber; Cyclic testing; Ductility; Engineered wood products; Sitka spruce; Strength degradation

资金

  1. Department of Agriculture, Food and the Marine of the Republic of Ireland [15/C/694]

向作者/读者索取更多资源

An investigation was carried out to examine the influence of the fastener length on the elastic and ductile failure behaviour of typical steel-to-timber bracket connections in Cross Laminated Timber (CLT) manufactured from C16 spruce. The behaviour of single screw-type fasteners within CLT of length 25 mm, 50 mm and 75 mm are examined under tension and shear loading. Multiple screw-type fasteners have been utilised to examine monotonic and cyclic behaviour of steel bracket-fastened CLT connections under shear and tension loading. Characteristic values of the experimental results are compared to analytical models from current timber design codes and the literature. The length of fastener has been shown to influence the failure strength and ductility of the connection. The overstrength factors and strength degradation factors have been shown to be similar, regardless of fastener length, and conservative values are recommended.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据