Active surfaces selection method for building-integrated photovoltaics (BIPV) in renovation projects based on self-consumption and self-sufficiency

期刊

ENERGY AND BUILDINGS
卷 193, 期 -, 页码 15-28

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.enbuild.2019.03.035

关键词

Renovation projects; Architectural design; Active surfaces; self-consumption; Self-sufficiency; Building-integrated photovoltaics

资金

  1. Swiss National Science Foundation (SNSF) [NRP 70, 407040_153965]
  2. Swiss National Science Foundation (SNF) [407040_153965] Funding Source: Swiss National Science Foundation (SNF)

向作者/读者索取更多资源

In light of the Paris Agreement's objectives and the related European and Swiss goals of decarbonising the built environment, the importance, relevance, and potential benefits of integrating Building-Integrated Photovoltaic (BIPV) within building renovation processes are acknowledged. Functioning both as envelope material and on-site electricity generator, BIPV can simultaneously reduce the use of fossil fuels and greenhouse gas emissions. Motivated by the current barriers and misconceptions that withhold a widespread integration of BIPV, particularly regarding financial implications and solar exposure levels that are believed to be unfavourable, this paper aims at bringing new knowledge and a rigorous and adaptable method to inform decision-making and promote the use of BIPV in urban renewal processes. Focusing on the architectural design, we here present a methodology to select active (BIPV) surfaces during the retrofitting process based on a trade-off between the self-consumption (SC) and self-sufficiency (SS) of a building. The approach consists in iteratively identifying surfaces that achieve a varying annual irradiation value (threshold). It also includes the evaluation of the effect of electricity storage systems. The methodology and the results of its application are presented through the comparison of two case studies in Neuchatel (Switzerland). The outcomes of this new approach for addressing building renovation projects in the urban context can help architects, designers and engineers to better size the installation and the repartition of active surfaces in the renovated thermal envelope. Results show that it is important to take into account a larger range of irradiation levels to choose the active surfaces, especially in high-rise buildings with a greater proportion of facade than roof. In such cases, the irradiation threshold can vary between 600 and 800 kWh/m(2).year depending on the strategy adopted in terms of Heating, Ventilation and Air-conditioning (HVAC) system improvement or storage system implementation. Such findings demonstrate the need for context-specific methods towards a proper evaluation and better valorisation of BIPV potential. (C) 2019 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据