4.7 Article

Determination of microcystins in environmental water samples with ionic liquid magnetic graphene

期刊

ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY
卷 176, 期 -, 页码 20-26

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.ecoenv.2019.03.063

关键词

Microcystin; Ionic liquid magnetic graphene; Magnetic solid phase extraction; Ultra high performance liquid chromatography; tandem mass spectrometry

资金

  1. National Natural Science Foundation of China [51778390]
  2. Major Project of Natural Science Foundation of the Higher Education Institutions of Jiangsu Province [15KJA610003]

向作者/读者索取更多资源

Microcystins is a class of monocyclic of heptapeptides with many different isomerides. It has become potential hazardous material in water environment for its toxic, distribution and stability. This project worked on a method for determination of trace microcystin (MC-LR and MC-RR) in environmental waters. The ionic liquid magnetic graphene (IL@MG) was prepared and applied to the concentration and determination of microcystins, based on magnetic solid phase extraction (MSPE), and coupled with ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). The ionic liquid magnetic graphene was prepared by co-precipitatial synthesis and characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), fourier transform infrared spectroscopy (FT-IR), specific surface area (BET), pore size distribution (BJH) and magnetic hysteresis loop. The experimental parameters of magnetic solid phase extraction, including amount of IL@MG, pH, extraction time and elution solvent were investigated by a univariate method and orthogonal screening. The method showed good linearity in the range of 0.01-10.0 g/L and 0.005-10.0 mu g/L for MC-LR and MC-RR, when the pH of water samples was 4.00 and 10.0 mg adsorbents were used to extract targets for 18 min. The lowest detection limit was 0.414 ng/L and 0.216 ng/L for MC-LR and MC-RR respectively. The recoveries of the microcystins were in the range of 83.6-100.9%, and the relative standard deviation was less than 7.59%. The trace amount of MC-LR (0.020 mu g/L) and MC-RR (0.003 mu g/L and 0.021 mu g/L) was detected in actural water samples. Attributed to its simple operator, low detection limit and high sensitivity, this method could be used for the detection of trace microcystins in water samples.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据