4.7 Article

AI-Assisted In Situ Detection of Human Glioma Infiltration Using a Novel Computational Method for Optical Coherence Tomography

期刊

CLINICAL CANCER RESEARCH
卷 25, 期 21, 页码 6329-6338

出版社

AMER ASSOC CANCER RESEARCH
DOI: 10.1158/1078-0432.CCR-19-0854

关键词

-

类别

资金

  1. NIH [R01CA218739, R01CA200399]
  2. Cancer Prevention and Research Institute of Texas [RP180588]
  3. Coulter H. Wallace Foundation
  4. FONDECYT-CONCYTEC Fellowship
  5. William J. and Charles H. Mayo Professorship
  6. Mayo Clinician Investigator award
  7. Mayo RACER award
  8. NSF-NCSA [XSEDE ASC170017]

向作者/读者索取更多资源

Purpose: In glioma surgery, it is critical to maximize tumor resection without compromising adjacent noncancerous brain tissue. Optical coherence tomography (OCT) is a noninvasive, label-free, real-time, high-resolution imaging modality that has been explored for glioma infiltration detection. Here, we report a novel artificial intelligence (AI)-assisted method for automated, real-time, in situ detection of glioma infiltration at high spatial resolution. Experimental Design: Volumetric OCT datasets were intraoperatively obtained from resected brain tissue specimens of 21 patients with glioma tumors of different stages and labeled as either noncancerous or glioma-infiltrated on the basis of histopathology evaluation of the tissue specimens (gold standard). Labeled OCT images from 12 patients were used as the training dataset to develop the AI-assisted OCT based method for automated detection of glioma-infiltrated brain tissue. Unlabeled OCT images from the other 9 patients were used as the validation dataset to quantify the method detection performance. Results: Our method achieved excellent levels of sensitivity (similar to 100%) and specificity (similar to 85%) for detecting glioma-infiltrated tissue with high spatial resolution (16 mu m laterally) and processing speed (similar to 100,020 OCT A-lines/second). Conclusions: Previous methods for OCT-based detection of glioma-infiltrated brain tissue rely on estimating the tissue optical attenuation coefficient from the OCT signal, which requires sacrificing spatial resolution to increase signal quality, and performing systematic calibration procedures using tissue phantoms. By overcoming these major challenges, our AI-assisted method will enable implementing practical OCT-guided surgical tools for continuous, real-time, and accurate intraoperative detection of glioma-infiltrated brain tissue, facilitating maximal glioma resection and superior surgical outcomes for patients with glioma.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据