4.4 Article

Acetabular revision arthroplasty using press-fitted jumbo cups: an average 10-year follow-up study

期刊

ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY
卷 139, 期 8, 页码 1149-1160

出版社

SPRINGER
DOI: 10.1007/s00402-019-03214-7

关键词

Acetabular revision; Jumbo cup; Migration; Wear

向作者/读者索取更多资源

IntroductionAcetabular revision arthroplasty using jumbo cups for moderate-to-severe acetabular defects has varied outcomes. We evaluated the clinical and radiological outcomes of acetabular revision arthroplasty using a press-fitted jumbo cup and sought to identify factors that influence outcomes during intermediate follow-up.Materials and methodsEighty patients (47 men, 33 women; 80 hips) who underwent acetabular revision arthroplasty using press-fitted jumbo cups were included. The mean follow-up period was 10.4years. Harris hip score (HHS), presence of groin pain, radiographic results, and Kaplan-Meier survival curves were evaluated. Implant design and surgery-related and patient-related factors were assessed to identify influential factors for cup loosening. Migration and wear analyses were performed using Einzel-Bild-Rontgen-Analyse software.ResultsThe mean preoperative HHS of 53 had improved to 77 at the final follow-up (p=0.005). Nine patients experienced groin pain. Acetabular cup loosening was observed in seven cups (8.7%), and one jumbo cup was replaced with a reinforcement cage. The survival rate of the acetabular cup was 91% at 16years according to the Kaplan-Meier analysis. Osteolysis was identified around the cup in six cases (7.5%). Acetabular cup loosening occurred more frequently in patients with conventional polyethylene liners than in those with highly cross-linked polyethylene liners (p=0.045). The mean total migration was 1.52mm, and the mean total wear was 0.98mm. There was a positive correlation between total migration and total wear (p=0.023; Spearman's rho=0.388). The mean wear rate of the patients with the cup inclination angle<50 degrees was significantly lower than those with the cup inclination angle>50 degrees (p=0.001). There were four cases of complications (three dislocations and one infection) that did not require revision surgery.ConclusionPress-fitted jumbo cups for acetabular revision arthroplasty exhibited encouraging results during follow-up for an average of 10years. Use of highly cross-linked polyethylene liners and proper placement of the acetabular component with an inclination angle<50 degrees may contribute to better clinical outcomes after acetabular revision arthroplasty with jumbo cups.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据