4.8 Article

A generalized model for wind turbine anomaly identification based on SCADA data

期刊

APPLIED ENERGY
卷 168, 期 -, 页码 550-567

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2016.01.133

关键词

Anomaly identification; Fuzzy synthetic evaluation; Generalized model; SCADA data; Wind turbine

资金

  1. National Key Basic Research Program of China (973 Program) [2012CB215205]
  2. Specialized Research Fund for the Doctoral Program of Higher Education of China (SRFDP) [20110191130004]
  3. State Key Lab of Power Transmission Equipment and System Security (SKLPES), Chongqing University, China
  4. National Natural Science Foundation of China [51321063]
  5. 111 Project of the Ministry of Education, China [B08036]
  6. National Science Foundation of USA [ECCS-1202133]
  7. Directorate For Engineering
  8. Div Of Electrical, Commun & Cyber Sys [1508910] Funding Source: National Science Foundation
  9. Div Of Electrical, Commun & Cyber Sys
  10. Directorate For Engineering [1202133] Funding Source: National Science Foundation

向作者/读者索取更多资源

This paper presents a generalized model for wind turbine (WT) anomaly identification based on the data collected from wind farm supervisory control and data acquisition (SCADA) system. Neural networks (NNs) are used to establish prediction models of the WT condition parameters that are dependent on environmental conditions such as ambient temperature and wind speed. Input parameters of the prediction models are selected based on the domain knowledge. Three types of sample data, namely the WT's current SCADA data, the WT's historical SCADA data, and other similar WTs' current SCADA data, are used to train the condition parameter prediction models. Prediction accuracy of the models trained by these sample data is compared and discussed in the paper. Mean absolute error (MAE) index is used to select the prediction models trained by historical and other similar WTs' current SCADA data. Abnormal level index (ALI) is defined to quantify the abnormal level of prediction error of each selected model. To improve the accuracy of anomaly identification, a fuzzy synthetic evaluation method is used to integrate the identification results obtained from the different selected models. The proposed method has been used for real 1.5 MW WTs with doubly fed induction generators. The results show that the proposed method is more effective in WT anomaly identification than traditional methods. (C) 2016 Elsevier Ltd. All rights reserved.