4.8 Article

Optimum design of horizontal ground-coupled heat pump systems using spiral-coil-loop heat exchangers

期刊

APPLIED ENERGY
卷 162, 期 -, 页码 330-345

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2015.10.113

关键词

Horizontal ground heat exchanger; Thermal response test; Numerical simulation; Parametric studies; Optimum design

资金

  1. Ministry of Land, Infrastructure and Transport (MOLIT)
  2. Regional Development Research Program - Ministry of Land, Infrastructure and Transport of the Korean government [15RDRP-B076564-02]

向作者/读者索取更多资源

This paper deals with an optimum design of horizontal ground heat pump systems for spiral-coil-loop heat exchangers. A three dimensional numerical analysis model simulating the thermal behavior of a horizontal spiral-coil-loop heat exchanger was developed, and the accuracy of the model was verified through indoor thermal response tests. After that, a total of 160 parametric studies were conducted using numerical simulation models in order to grasp the degree of effects that key input parameters used in the model would have on the output. Then, an optimum design condition for horizontal ground coupled heat pump system was suggested using several economic analysis tools. Economic analysis factors, such as internal rate of return, savings to investment ratio, and simple payback period, show that certain design conditions (coil pitch: 0.08 m, setting depth: 2.5 m, circulating fluid velocity: 0.7 m s(-1)) provide the most economic feasibility. However, this condition also varies with the unit cost of operation and initial investment. (C) 2015 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据