4.8 Article

Metal Replacement Causing Interference in Stripping Analysis of Multiple Heavy Metal Analytes: Kinetic Study on Cd(II) and Cu(II) Electroanalysis via Experiment and Simulation

期刊

ANALYTICAL CHEMISTRY
卷 91, 期 15, 页码 9978-9985

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.9b01724

关键词

-

资金

  1. National Natural Science Foundation of China [21802145, 21735005]
  2. Postdoctoral Innovation Talents Supporting Project [BX20180311]
  3. Science and Technology Major Project of Anhui Province [17030801033]
  4. Key Program of 13th five-year plan, Hefei Institutes of Physical Science, Chinese Academy of Sciences (CAS)
  5. CAS Interdisciplinary Innovation Team, Chinese Academy of Sciences, China

向作者/读者索取更多资源

Although it has been recognized that the interference between heavy metal ions (HMIs) becomes a severe problem for the simultaneous electroanalysis of multiple HMIs, the factor leading to the interference is still difficult to identify, due to the limited understanding of the electroanalytic kinetics. In this work, a kinetic model is built for the electroanalysis of HMIs, and the electroanalytic results are simulated for Cd(II), Cu(II), and their mixture as examples for the interference investigation. The mutual interference between Cd and Cu is observed on the glassy carbon electrode. By applying the kinetic model, the replacement of deposited Cd by Cu(II) at the codeposition stage is regarded as the main reason for the interference, and the corresponding suggestion for selecting suitable electrode materials to avoid such interference is also provided.