4.7 Article

Simultaneous analysis of natural pigments and E-141i in olive oils by liquid chromatography-tandem mass spectrometry

期刊

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
卷 411, 期 21, 页码 5577-5591

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-019-01939-3

关键词

Natural pigments; Olive oil; Atmospheric pressure chemical ionization; Atmospheric pressure photoionization; Ultra-high-performance liquid chromatography-tandem mass spectrometry

资金

  1. Spanish Ministry of Economy and Competitiveness [CTQ2015-63968-C2-P]
  2. Agency for Management of University and Research Grants (Government of Catalonia, Spain) [2017SGR-310]
  3. Agency for Management of University and Research Grants (Government of Catalonia)
  4. European Social Fund

向作者/读者索取更多资源

This work describes the development of an ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for the determination of carotenoids (beta-carotene, lutein, beta-criptoxanthin, neoxanthin, violaxanthin) and chlorophylls, as well as their related compounds (chlorophyll A and B, pheophytin A and B and the banned dyes Cu-pyropheophytin A, Cu-pheophytin A and B) in olive oils. For this purpose, the feasibility of electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) for the ionization of these compounds was evaluated and compared. Tandem mass spectrometry (MS/MS) fragmentation was discussed for each family of compounds, and the most characteristic and abundant product ions were selected to propose a selective and sensitive UHPLC-MS/MS method. The best results were obtained using APCI and APPI, while ESI provided the worst signal-to-noise ratio (S/N) for all compounds. For the analysis of olive oils, a simple solid-phase extraction (SPE) with silica cartridges was applied before the determination by UHPLC-MS/MS (APCI and APPI) in multiple reaction monitoring (MRM) mode. Method quality parameters were stablished, and the results demonstrate the good performance of the new methods, providing low limits of detection (0.004-0.9 mg L-1), high extraction efficiencies (62-95%) and low matrix effects (< 25%). The developed UHPLC-API-MS/MS (APCI and APPI) methods were applied to the analysis of olive oil samples, and beta-carotene, pheophytin A, pheophytin B and lutein were detected and quantified in all of them at concentrations ranging from 0.1 to 9.5 mg L-1.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据