4.4 Article

Plan-library supported automated replanning for online-adaptive intensity-modulated proton therapy of cervical cancer

期刊

ACTA ONCOLOGICA
卷 58, 期 10, 页码 1440-1445

出版社

TAYLOR & FRANCIS LTD
DOI: 10.1080/0284186X.2019.1627414

关键词

Cervical cancer; online-adaptive proton therapy; online treatment planning; plan-library; intensity-modulated proton therapy (IMPT)

类别

资金

  1. ZonMw, the Netherlands Organization for Health Research and Development [104003012]
  2. Varian Medical Systems

向作者/读者索取更多资源

Background: Intensity-modulated proton therapy is sensitive to inter-fraction variations, including density changes along the pencil-beam paths and variations in organ-shape and location. Large day-to-day variations are seen for cervical cancer patients. The purpose of this study was to develop and evaluate a novel method for online selection of a plan from a patient-specific library of prior plans for different anatomies, and adapt it for the daily anatomy. Material and methods: The patient-specific library of prior plans accounting for altered target geometries was generated using a pretreatment established target motion model. Each fraction, the best fitting prior plan was selected. This prior plan was adapted using (1) a restoration of spot-positions (Bragg peaks) by adapting the energies to the new water equivalent path lengths; and (2) a spot addition to fully cover the target of the day, followed by a fast optimization of the spot-weights with the reference point method (RPM) to obtain a Pareto-optimal plan for the daily anatomy. Spot addition and spot-weight optimization could be repeated iteratively. The patient cohort consisted of six patients with in total 23 repeat-CT scans, with a prescribed dose of 45 Gy(RBE) to the primary tumor and the nodal CTV. Using a 1-plan-library (one prior plan based on all motion in the motion model) was compared to choosing from a 2-plan-library (two prior plans based on part of the motion). Results: Applying the prior-plan adaptation method with one iteration of adding spots resulted in clinically acceptable target coverage ( and ) for 37/46 plans using the 1-plan-library and 41/46 plans for the 2-plan-library. When adding spots twice, the 2-plan-library approach could obtain acceptable coverage for all scans, while the 1-plan-library approach showed for 3/46 plans. Similar OAR results were obtained. Conclusion: The automated prior-plan adaptation method can successfully adapt for the large day-to-day variations observed in cervical cancer patients.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据