4.5 Article

BabyLux device: a diffuse optical system integrating diffuse correlation spectroscopy and time-resolved near-infrared spectroscopy for the neuromonitoring of the premature newborn brain

期刊

NEUROPHOTONICS
卷 6, 期 2, 页码 -

出版社

SPIE-SOC PHOTO-OPTICAL INSTRUMENTATION ENGINEERS
DOI: 10.1117/1.NPh.6.2.025007

关键词

preterm infants; diffuse correlation spectroscopy; time-resolved near-infrared spectroscopy; neuromonitoring

资金

  1. European Commission Competitiveness for Innovation Program [620996]
  2. Fundacio CELLEX Barcelona
  3. Ministerio de Economia y Competitividad/FEDER (PHOTODEMENTIA) [DPI2015-64358-C2-1-R]
  4. Instituto de Salud CarlosIII/FEDER (MEDPHOTAGE) [DTS16/00087]
  5. Severo Ochoa Programme for Centres of Excellence in RD [SEV-2015-0522]
  6. Obra social la Caixa Foundation (LlumMedBcn)
  7. Institucio CERCA
  8. AGAUR-Generalitat [2017 SGR 1380]
  9. LASERLABEUROPE IV [GA: 654148]

向作者/读者索取更多资源

The BabyLux device is a hybrid diffuse optical neuromonitor that has been developed and built to be employed in neonatal intensive care unit for the noninvasive, cot-side monitoring of microvascular cerebral blood flow and blood oxygenation. It integrates time-resolved near-infrared and diffuse correlation spectroscopies in a user-friendly device as a prototype for a future medical grade device. We present a thorough characterization of the device performance using test measurements in laboratory settings. Tests on solid phantoms report an accuracy of optical property estimation of about 10%, which is expected when using the photon diffusion equation as the model. The measurement of the optical and dynamic properties is stable during several hours of measurements within 3% of the average value. In addition, these measurements are repeatable between different days of measurement, showing a maximal variation of 5% in the optical properties and 8% for the particle diffusion coefficient on a liquid phantom. The variability over test/retest evaluation is <3%. The integration of the two modalities is robust and without any cross talk between the two. We also perform in vivo measurements on the adult forearm during arterial cuff occlusion to show that the device can measure a wide range of tissue hemodynamic parameters. We suggest that this platform can form the basis of the next-generation neonatal neuromonitors to be developed for extensive, multicenter clinical testing. (C) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据