4.5 Article

Field Validation of Demanded Power Point Tracking Control Algorithm for Medium-Capacity Wind Turbine

出版社

KOREAN SOC PRECISION ENG
DOI: 10.1007/s40684-019-00107-3

关键词

Demand power point tracking control; Active power control; Wind field test; Medium-capacity wind turbine

资金

  1. Korea Institute of Energy Technology Evaluation and Planning (KETEP) - Korea government (MOTIE) [20183010025440, 20184030201940]
  2. Korea Evaluation Institute of Industrial Technology (KEIT) [20183010025440, 20184030201940] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

In this paper, the previously proposed demanded power point tracking (DPPT) control is applied to a medium-capacity wind turbine. Based on the results of our previous studies, the control algorithm has modified to be advantageous for wind farm control and load reduction of individual wind turbines. The target turbine is a medium-capacity turbine with a rated power of 100 kW and uses direct drive-train and integrated pitch control via hydraulic pressure. Experiments were carried out for each of 100%, 30%, and 20% of the rated power with natural wind conditions at an onshore test bed in Jeju Island in South Korea. The performance data was measured at a sampling frequency of 2 Hz by changing the power command. Test results show that the power is limited by the control method presented in accordance with the power command. In addition, it is confirmed that the turbine operates similarly to the in-house simulation model.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据