4.7 Article Proceedings Paper

Chemo-mechanical effects on the tribocorrosion behavior of titanium/ceramic dental implant pairs in artificial saliva

期刊

WEAR
卷 426, 期 -, 页码 162-170

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.wear.2018.12.052

关键词

Tribocorrosion; Titanium; Ceramic; Dental

资金

  1. Generalitat Valenciana [APOSTD/2017/051, PROMETEO/2016/040, GV/2017/042]

向作者/读者索取更多资源

In this paper, the degradation mechanisms of the ceramic and the metal in Titanium/Zirconia pairs for biomedical applications were analyzed. To do that, an experimental set-up with well-controlled mechanical and chemical conditions was used based on a unidirectional ball-on-disk tribometer coupled to a potentiostat. Tribocorrosion tests were carried out in artificial saliva at different applied potentials, this is, different chemical conditions of the surface. Wear damage of the titanium/zirconia pair was influenced by the properties and the behavior of wear debris in the contact. Under passive conditions metallic and oxidized titanium particles (formed by the cyclic removal of the passive film and subsequent repassivation) were smeared and mechanically mixed within the contact forming compacted wear debris through which the loading was carried out. Properties and amount of oxidized titanium lead to low wear at low passive conditions (OCP) and higher wear at high passive conditions. Zirconia did not suffer any damage under all the studied conditions and oxidized titanium was transferred to the ball at anodic applied potentials.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据