4.7 Article

Indoor particulate matter and lung function in children

期刊

SCIENCE OF THE TOTAL ENVIRONMENT
卷 663, 期 -, 页码 408-417

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.scitotenv.2019.01.309

关键词

Indoor particles; Lung function; Asthmatic children; Outdoor particles; Light absorbing particles

资金

  1. United States Department of Housing and Urban Development [OHHHU0027-14]
  2. Department of Environmental Health University of Cincinnati Graduate Scholarship
  3. National Institutes of Health [P30ES009089]

向作者/读者索取更多资源

People generally spend more time indoors than outdoors resulting in a higher proportion of exposure to particulate matter (PM) occurring indoors. Consequently, indoor PM levels, in contrast to outdoor PM levels, may have a stronger relationship with lung function. To test this hypothesis, indoor and outdoor PM2.5 and fungal spore data were simultaneously collected from the homes of forty-four asthmatic children aged 10-16 years. An optical absorption technique was utilized on the collected PM2.5 mass to obtain concentrations of black carbon (BC) and ultraviolet light absorbing particulate matter, (UVPM; a marker of light absorbing PM2.5 emitted from smoldering organics). Enrolled children completed spirometry after environmental measurements were made. Given the high correlation between PM2.5, BC, and UVPM, principal component analysis was used to obtain uncorrelated summaries of the measured PM. Separate linear mixed-effect models were developed to estimate the association between principal components of the PM variables and spirometry values, as well as the uncorrelated original PM variables and spirometry values. A one-unit increase in the first principal component variable representing indoor PM(predominantly composed of UVPM and PM2.5) was associated with 4.1% decrease (99% CI=-6.9,-1.4) in FEV1/FVC ratio. 11.3 mu g/m(3) increase in indoor UVPM was associated with 6.4% and 14.7% decrease (99% CI=-10.4, -2.4 and 99% CI=-26.3, -2.9, respectively) in percent predicted FEV1/FVC ratio and FEF25-75 respectively. Additionally, 17.7 mu g/m(3) increase in indoor PM2.5 was associated with 6.1% and 12.9% decrease (99% CI = -10.2, -1.9 and 99% CI = -24.9, -1.0, respectively) in percent predicted FEV1/FVC ratio and FEF25-75, respectively. Outdoor PM, indoor BC, and indoor fungal spores were not significantly associated with lung function. The results indicate that indoor PM is more strongly associated with lung function in children with asthma as compared with outdoor PM. (C) 2019 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据