4.7 Article

Digital Mammography versus Digital Mammography Plus Tomosynthesis in Breast Cancer Screening: The Oslo Tomosynthesis Screening Trial

期刊

RADIOLOGY
卷 291, 期 1, 页码 22-29

出版社

RADIOLOGICAL SOC NORTH AMERICA
DOI: 10.1148/radiol.2019182394

关键词

-

资金

  1. Hologic

向作者/读者索取更多资源

Background: Digital breast tomosynthesis (DBT) is replacing digital mammography (DM) in the clinical workflow. Currently, there are limited prospective studies comparing the diagnostic accuracy of both examinations and the role of synthetic mammography (SM) and computer-aided detection (CAD). Purpose:To compare the accuracy of DM versus DM + DBT in population-based breast cancer screening. Materials and Methods: This prospective study, performed from November 2010 to December 2012, included 24 301 women (mean age, 59.1 years +/- 5.7 [standard deviation]) with 281 cancers, of which 51 were interval cancers. Each examination was independently interpreted with four reading modes: DM, DM + CAD, DM + DBT, and SM + DBT. Sensitivity and specificity were compared for DM versus DM + DBT, DM versus DM + CAD, DM + DBT versus SM + DBT, and DM versus DM + DBT at double reading. Reader-adjusted performance characteristics of reading modes were evaluated on the basis of pre-arbitration (initial interpretation) scores. Statistical analysis was based on cluster bootstrap analysis using 10 000 random resamples. Results: Sensitivity was 54.1% (152 of 281) for DM and 70.5% (198 of 281) for DM + DBT. Reader-adjusted difference was 12.6% (95% confidence interval [CI]: 5.2%, 19.7%; p = .001). Specificity was 94.2% (false-positive fraction [FPF], 5.8%; 1388 of 24020) for DM and 95.0% (FPF, 5.0%; 1209/24020) for DM + DBT, with a reader-adjusted difference in FPF of -1.2% (95% CI: -1.7%, -0.7%; p < .001). Sensitivity was 69.0% (194 of 281) for SM + DBT and 70.5% (198 of 281) for DM + DBT, with a reader-adjusted difference of 1.0% (95% CI: -6.2%, 8.5%; p = .77). Specificity was 95.4% (FPF, 4.6%; 1111 of 24020) for SM + DBT and 95.0% (FPF, 5.0%;1209 of 24020) for DM + DBT, with reader-adjusted 95% CIs for FPF of 4.7%, 5.4% and 5.0%, 5.7%, respectively, and a difference of -0.3% (95% CI: -0.8%, 0.2%; p = .23). Differences in sensitivity and specificity with the addition of CAD were small and not significant (p > .2). Conclusion: Addition of digital breast tomosynthesis digit mammography resulted in significant gains in sensitivity and specificity. Synthetic mammography in combination with digital breast tomosynthesis had similar sensitivity and specificity to digital mammography in combination with digital breast tomosynthesis. (C) RSNA, 2019

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据