4.3 Article

The Importance of the Location of Dorsal Root Ganglion Stimulator Electrodes Within the Nerve Root Exit Foramen

期刊

NEUROMODULATION
卷 23, 期 2, 页码 245-251

出版社

WILEY
DOI: 10.1111/ner.12959

关键词

Chronic pain; dorsal root ganglion stimulation; implantable pulse generator; power consumption

向作者/读者索取更多资源

Objective To quantify the relationship between the electrical power requirement to achieve pain relief and the position of the active electrode of dorsal root ganglion stimulators within the spinal nerve root exit foramen. Materials and Methods Retrospective analysis of prospectively collected data of 92 consecutive patients undergoing dorsal root ganglion stimulation (DRGS) for chronic pain in a single center. Cervical and sacral cases, and failed trials/explanted DRGS were excluded, so we report on 57 patients with 78 implanted leads. Anteroposterior and lateral fluoroscopic images of the lead in the exit foramen were examined, and the active electrode positions were put into categories depending on their location relative to fixed anatomical landmarks. The clinical outcome and the power requirements for each of these groups of electrodes were then analyzed. Overall pain outcome was assessed by numeric pain rating scale score pre-operatively and post-operatively. Results There was no significant relationship between power requirements and mediolateral electrode position, although the lowest average was observed with electrode positions directly below the center of the pedicle. On lateral x-ray, the lowest power requirements were observed in the electrodes positioned superodorsally or dorsally within the foramen. Importantly, power requirements in this location were consistently low, while the power requirements in other locations were not only higher but also much more variable. Electrodes in the superodorsal position required a median output power almost four times lower than electrodes in other positions (p = 0.002). Clinical outcome was not significantly related to power requirement or foraminal position. Conclusion Aiming for a superodorsal electrode position on lateral intraoperative fluoroscopy is desirable, since siting leads in this location reduces the required stimulator output power very substantially and thus will extend battery life. Position within the foramen does not determine clinical outcome, and so the implanter can safely aim for the low power site without detriment to the analgesic efficacy of the system.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据