4.5 Article Proceedings Paper

Five-year results from the Study of Thoracic Aortic Type B Dissection Using Endoluminal Repair (STABLE I) study of endovascular treatment of complicated type B aortic dissection using a composite device design

期刊

JOURNAL OF VASCULAR SURGERY
卷 70, 期 4, 页码 1072-+

出版社

MOSBY-ELSEVIER
DOI: 10.1016/j.jvs.2019.01.089

关键词

Aorta; Dissection; Type B; TEVAR; Bare stent

资金

  1. Cook Medical

向作者/读者索取更多资源

Objective: We report the final 5-year results from the Study of Thoracic Aortic Type B Dissection Using Endoluminal Repair (STABLE I) study, a prospective, single-arm, multicenter study of the Zenith Dissection Endovascular System (William Cook Europe, Aps, Bjaeverskov, Denmark), a pathology-specific device comprising a proximal stent graft with barbs and a distal bare stainless steel stent for the treatment of patients with complicated type B aortic dissection. Methods: The study prospectively enrolled 86 patients (mean age, 59 years; 73% male) at sites in the United States, Europe, and Australia from 2007 to 2012. Treatment occurred during the acute phase (<= 14 days after symptom onset) in 55 patients and during the nonacute phase (>14 days; all treated <= 90 days) in 31 patients. Five-year clinical and imaging follow-up was available for 88.5% of eligible patients. Results: The 30-day all-cause mortality rate was 5.5% (3 of 55) for acute and 3.2% (1 of 31) for nonacute patients (P > .99). The 5-year freedom from all-cause mortality was 79.9% +/- 6.2% for acute and 70.1% +/- 8.4% for nonacute patients (log-rank test, P = .40). The 5-year freedom from dissection-related mortality (including deaths of indeterminate relatedness to dissection repair) was 83.9% +/- 5.9% for acute and 90.1% +/- 5.9% for nonacute patients (log-rank test, P = .55). Complete false lumen thrombosis in the thoracic aorta increased over time and was observed in 74.1% of acute and in 58.8% of nonacute patients at 5 years. From preprocedure through 5 years, there was an overall increase in true lumen diameter and a concomitant decrease in false lumen diameter in both acute and nonacute patients at the level of the largest diameter in both the thoracic and abdominal aortas. At 5 years, 65.5% of acute and 81.3% of nonacute patients exhibited a stable or shrinking transaortic diameter in the thoracic aorta, and 48.3% of acute and 76.5% of nonacute patients had a stable or shrinking transaortic diameter in the abdominal aorta. Freedom from secondary intervention at 5 years was 65.5% +/- 7.5% for acute and 71.2% +/- 9.0% for nonacute patients (log-rank test, P = .71). Conclusions: Endovascular repair of complicated type B aortic dissection with a composite device design demonstrated low all-cause mortality at 30 days, as well as low dissection-related mortality throughout follow-up. Overall, the acute and nonacute cohorts appeared to respond similarly to treatment involving use of the stent-graft and bare metal stent, demonstrating similar clinical outcomes and favorable improvement in aortic remodeling in the thoracic and abdominal aortas.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据