4.4 Article

Anaerobic Threshold in a Water-Based Exercise: Agreement Between Heart Rate Deflection Point and Lactate Threshold Methods

期刊

JOURNAL OF STRENGTH AND CONDITIONING RESEARCH
卷 35, 期 9, 页码 2472-2478

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1519/JSC.0000000000003161

关键词

rating of perceived exertion; water aerobics; stationary running; young men

资金

  1. Foundation for Research Support of the State of Rio Grande of the South (FAPERGS), Brazil [1926-2551/13-7]

向作者/读者索取更多资源

In a study comparing HR and RPE corresponding to anaerobic threshold methods during water-based exercise in young men, it was found that there was agreement between HRDP and LT methods for HR, but RPE values were significantly higher in the HRDP method, indicating a lack of acceptable agreement between the two methods. Strong relationships were verified between methods of AT determination for HR and RPE. The HR determined by HRDP may be a valid parameter used for intensity prescription in water-based exercise programs for young men.
Alberton, CL, Andrade, LS, Pinheiro, RB, and Pinto, SS. Anaerobic threshold in a water-based exercise: agreement between heart rate deflection point and lactate threshold methods. J Strength Cond Res 35(9): 2472-2478, 2021-The purpose of this study was to compare and assess the agreement of the heart rate (HR) and rating of perceived exertion (RPE) corresponding to the anaerobic threshold (AT) between HR deflection point (HRDP) and lactate threshold (LT) methods during a water-based exercise in young men. Sixteen young men (24 +/- 6 years) performed the experimental protocol, which comprised the performance of a maximal incremental test during the water-based stationary running exercise. The initial cadence corresponded to 90 b center dot min(-1), with 10 b center dot min(-1) increases every 3 minutes up to exhaustion. Heart rate was monitored every 30 seconds while blood lactate concentrations and RPE were measured at the end of each 3-minute bout. Anaerobic threshold was identified by HRDP and LT methods by experienced physiologists. Paired Student's t-test, Bland-Altman analysis, and Pearson correlation were used for data analysis (alpha = 0.05). As results, there was agreement between HRDP and LT methods for HR, while RPE presented significant higher values for the HRDP method, resulting in an absence of acceptable agreement between methods. In addition, strong relationships (p <= 0.001) were verified between methods of AT determination for HR (r = 0.786) and RPE (r = 0.916). Therefore, based on the agreement between HRDP and LT methods, the HR determined by HRDP may be a valid parameter used for the intensity prescription of water-based stationary running exercise in young men during water aerobics programs and may be considered more reliable than RPE.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据