4.7 Article

On the Field Strength Dependence of Bi- and Triexponential Intravoxel Incoherent Motion (IVIM) Parameters in the Liver

期刊

JOURNAL OF MAGNETIC RESONANCE IMAGING
卷 50, 期 6, 页码 1883-1892

出版社

WILEY
DOI: 10.1002/jmri.26730

关键词

intravoxel incoherent motion; IVIM; liver

资金

  1. Deutsche Forschungsgemeinschaft [LA 2804/6-1]

向作者/读者索取更多资源

Background Studies on intravoxel incoherent motion (IVIM) imaging are carried out with different acquisition protocols. Purpose To investigate the dependence of IVIM parameters on the B-0 field strength when using a bi- or triexponential model. Study Type Prospective. Study Population 20 healthy volunteers (age: 19-28 years). Field Strength/Sequence Volunteers were examined at two field strengths (1.5 and 3T). Diffusion-weighted images of the abdomen were acquired at 24 b-values ranging from 0.2 to 500 s/mm(2). Assessment ROIs were manually drawn in the liver. Data were fitted with a bi- and a triexponential IVIM model. The resulting parameters were compared between both field strengths. Statistical Tests One-way analysis of variance (ANOVA) and Kruskal-Wallis test were used to test the obtained IVIM parameters for a significant field strength dependency. Results At b-values below 6 s/mm(2), the triexponential model provided better agreement with the data than the biexponential model. The average tissue diffusivity was D = 1.22/1.00 mu m(2)/msec at 1.5/3T. The average pseudodiffusion coefficients for the biexponential model were D* = 308/260 mu m(2)/msec at 1.5/3T; and for the triexponential model D1* = 81.3/65.9 mu m(2)/msec, D2* = 2453/2333 mu m(2)/msec at 1.5/3T. The average perfusion fractions for the biexponential model were f = 0.286/0.303 at 1.5/3T; and for the triexponential model f(1) = 0.161/0.174 and f(2) = 0.152/0.159 at 1.5/3T. A significant B-0 dependence was only found for the biexponential pseudodiffusion coefficient (ANOVA/KW P = 0.037/0.0453) and tissue diffusivity (ANOVA/KW: P < 0.001). Data Conclusion Our experimental results suggest that triexponential pseudodiffusion coefficients and perfusion fractions obtained at different field strengths could be compared across different studies using different B-0. However, it is recommended to take the field strength into account when comparing tissue diffusivities or using the biexponential IVIM model. Considering published values for oxygenation-dependent transversal relaxation times of blood, it is unlikely that the two blood compartments of the triexponential model represent venous and arterial blood. Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2019.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据