4.4 Article

Study of Entropy Generation in Heat Exchanger Tube With Multiple V Cuts in Perforated Twisted Tape Insert

出版社

ASME
DOI: 10.1115/1.4043769

关键词

perforated twisted tape with V cuts; twist ratio; Nusselt number; friction factor; entropy generation

向作者/读者索取更多资源

The present work deals with the study of entropy generation in circular tube fitted with perforated twisted tape (PTT) insert with multiple V cuts. Experimental data pertaining to heat transfer and frictional losses are collected for solid twisted tape (STT), PTT, double V cut PTT, and PTT with multiple V cuts by varying the twist ratio in the range of 2-6 for the Reynolds number range of 2000-25,000. The entropy generation rate of heated tube with insert is found to be less than the smooth tube in most of the cases under similar operating conditions. The minimum value of entropy generation number corresponds to the PTT having twist ratio of 3.