4.6 Article

Non-Destructive Testing of Ceramic Knee Implants Using Micro-Computed Tomography

期刊

JOURNAL OF ARTHROPLASTY
卷 34, 期 9, 页码 2111-2117

出版社

CHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS
DOI: 10.1016/j.arth.2019.05.006

关键词

ceramic; tibia; femur; non-destructive testing; strength; burst

资金

  1. EFRE [ATCZ38]
  2. K-Project [871974]
  3. COMET program of FFG
  4. federal government of Upper Austria
  5. federal government of Styria

向作者/读者索取更多资源

Background: Because of the accumulated numbers and the increasing rate of knee replacement surgeries larger numbers of revision cases are likely. Although the success rate of knee arthroplasties is high, complications like the loosening of the implant necessitate subsequent treatments. Therefore, new concepts such as metal-free ceramic implants are necessary, for example, using zirconium dioxide (ZrO2). Several studies showed that the strength of ceramic ZrO2 implants is equivalent to cobalt-chromium components. Methods: Non-destructive testing remains challenging due to the high density (6 g/cm(3)) of ZrO2. In this feasibility study, we investigated 8 tibial and 8 femoral implants respectively using an industrial X-ray micro-computed tomography (XCT) system at a voxel size of 100 mm. We established a non-destructive testing protocol for ceramic knee implants optimizing scanning parameters and sample orientation using CT simulations. Finally, we used an iterative artifact reduction procedure for beam hardening correction. Results: The results show that corrected image data enable the non-destructive inspection of high-density components. In this sample, none of the investigated components show any internal defects like pores or cracks. In general, XCT is a major imaging method that is able to provide a 3-dimensional representation of higher dense objects that allows the inspection of metal or ceramic knee implants. Even though we established an optimized scanning routine for tibial and femoral ceramic components, it is not possible to completely eliminate scanning artifacts of XCT. Conclusion: Altogether, after visual inspection, none of the beam-hardening corrected XCT data sets for femoral and tibial implants showed any defects, that is, no inclusions, cracks, or pores were detected. XCT test is therefore an essential addition to the fatigue testing since it is the only non-destroying testing method. (C) 2019 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据