4.3 Article

Motion-corrected free-breathing LGE delivers high quality imaging and reduces scan time by half: an independent validation study

期刊

INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING
卷 35, 期 10, 页码 1893-1901

出版社

SPRINGER
DOI: 10.1007/s10554-019-01620-x

关键词

Late gadolinium enhancement; Image quality; Cardiac imaging; Fibrosis

资金

  1. European Association of Cardiovascular Imaging
  2. NATIONAL HEART, LUNG, AND BLOOD INSTITUTE [ZIAHL006214, ZIAHL006242] Funding Source: NIH RePORTER

向作者/读者索取更多资源

Late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) sequences have evolved. Free-breathing motion-corrected (MOCO) LGE has potential advantages over breath-held (bh) LGE including minimal user input for the short axis (SAX) stack without breath-holds. It has previously been shown that MOCO-LGE delivers high image quality compared to bh-LGE. We sought to conduct an independent validation study to investigate real-world performance of bh-LGE versus MOCO-LGE in a high-throughput CMR center immediately after the introduction of the MOCO-LGE sequence and with elementary staff induction in its use. Four-hundred consecutive patients, referred for CMR and graded by clinical complexity, underwent CMR on either of two scanners (1.5 T, both Siemens) in a UK tertiary cardiac center. Scar imaging was by bh-LGE or MOCO-LGE (both with phase sensitive inversion recovery). Image quality, scan time, reader confidence and report reproducibility were compared between those scanned by bh-LGE versus MOCO-LGE. Readers had > 3 years CMR experience. Categorical variables were compared by chi(2) or Fisher's exact tests and continuous variables by unpaired Student's t-test. Inter-rater agreement of LGE reports was by Cohen's kappa. Image quality (low score = better) was better for MOCO-LGE (median, interquartile range [Q1-Q3]: 0 [0-0] vs. 2 [0-3], P < 0.0001). This persisted when just clinically complex patients were assessed (0 [0-1] vs. 2 [1-4] P < 0.0001). Readers were more confident in their MOCO-LGE rulings (P < 0.001) and reports more reproducible [bh-LGE vs. MOCO-LGE: kappa 0.76, confidence interval (CI) 0.7-0.9 vs. 0.82, CI 0.7-0.9]. MOCO-LGE significantly shortened LGE acquisition times compared to bh-LGE (for left ventricle SAX stack: 03:22 +/- 01:14 vs 06:09 +/- 01:47 min respectively, P < 0.0001). In a busy clinical service, immediately after its introduction and with elementary staff training, MOCO-LGE is demonstrably faster to bh-LGE, providing better images that are easier to interpret, even in the sickest of patients.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据