4.5 Article

Hydrodynamics of two-phase flow in a rod bundle under cross-flow condition

期刊

ANNALS OF NUCLEAR ENERGY
卷 91, 期 -, 页码 206-214

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.anucene.2016.01.025

关键词

Pressure drop experiments; Two-phase flow; Horizontal rod bundle; New correlation; Numerical simulation

资金

  1. Ministry of Education, China [IRT1280]

向作者/读者索取更多资源

Pressure drop experiments were conducted for a vertical two-phase air-water flow across a horizontal staggered rod bundle under conditions of air quality ranging from 0.001 to 0.3 and mass velocity ranging from 80 to 500 kg/(m(2) s). The experimental data were thoroughly analyzed and compared with predictions from existing correlations. New developed expressions provided the most accurate predictions. The two-phase friction multipliers for G <= 200 kg/(m(2) s), which show a strong mass velocity effect, could be fit well in terms of the Martinelli parameter and the dimensionless mass velocity. The new correlation developed for the two-phase friction multiplier was successfully tested in predicting the experimental data for G <= 200 kg/(m(2) s) in previous experiments of other researchers. Distributions of velocity and turbulent intensity were also obtained from the numerical simulation on single-phase flow of water using the CFD code ANSYS FLUENT 14.0. The SST k-omega model was verified to be the best turbulent model to gain flow characteristics in the horizontal rod bundle under experimental conditions. (C) 2016 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据